2022
DOI: 10.3390/s22249868
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study on a Novel Quality Assessment Protocol Based on Image Analysis Methods for Color Doppler Ultrasound Diagnostic Systems

Abstract: Color Doppler (CD) imaging is widely used in diagnostics since it allows real-time detection and display of blood flow superimposed on the B-mode image. Nevertheless, to date, a shared worldwide standard on Doppler equipment testing is still lacking. In this context, the study herein proposed would give a contribution focusing on the combination of five test parameters to be included in a novel Quality Assessment (QA) protocol for CD systems testing. A first approach involving the use of the Kiviat diagram was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(11 citation statements)
references
References 46 publications
(83 reference statements)
0
11
0
Order By: Relevance
“…An uncertainty analysis was also conducted based on the main sources of error, these included the uncertainty on the pixel resolution of the CT images, while the uncertainty of the measurement image analysis was evaluated by a Monte Carlo simulation [23][24][25][26] with 10 4 iterations where the grey level threshold value for the mask of the replicas was made to vary randomly through a uniform distribution with ± 5% bounds. For a first estimation of the overall measurement uncertainty, shown in Table 3 and in Table 4, the above two uncertainty contributions were combined together by applying the uncertainty propagation law.…”
Section: Ct Parameter Settingmentioning
confidence: 99%
“…An uncertainty analysis was also conducted based on the main sources of error, these included the uncertainty on the pixel resolution of the CT images, while the uncertainty of the measurement image analysis was evaluated by a Monte Carlo simulation [23][24][25][26] with 10 4 iterations where the grey level threshold value for the mask of the replicas was made to vary randomly through a uniform distribution with ± 5% bounds. For a first estimation of the overall measurement uncertainty, shown in Table 3 and in Table 4, the above two uncertainty contributions were combined together by applying the uncertainty propagation law.…”
Section: Ct Parameter Settingmentioning
confidence: 99%
“…In diagnostic ultrasound (US), Quality Assessment (QA) protocols are deemed necessary in order to monitor the performance level of the imaging equipment over time and detect any non-conformities [1][2][3]. Progressive worsening of US system performance usually occurs as a slow worsening of the image quality that could impact clinical decision, increasing the risk of misdiagnosis [4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%
“…Although several professional organizations attempted to define guidelines for ultrasound QA over the years [9][10][11][12], a shared worldwide reference standard has yet to be developed [1,13]. This is associated, among other factors, with the presence of diverse performance parameters, and with the lack of a comprehensive approach to QA [1,3,13]. On this point, Kiviat diagrams have been introduced in [3] to effectively combine experimental test parameters for Color Doppler QA.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations