2000
DOI: 10.1002/1097-0231(20000830)14:16<1558::aid-rcm64>3.0.co;2-3
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of laser spray and electrospray

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
32
0

Year Published

2001
2001
2012
2012

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 24 publications
(36 citation statements)
references
References 13 publications
(24 reference statements)
4
32
0
Order By: Relevance
“…Other activation methods, prompt heating of the inlet of the sample solution, for example, might be effective for more quantitative analysis of the dissociation [21]. We are now trying to apply laser spray, developed by Hiraoka et al [22,23], for quantification of binding affinity of c-Myb DBD-dsDNA complexes [24]. This technique might be promising for the quantification of binding affinity of complexes stabilized mainly by hydrogen bonds and/or electrostatic interactions.…”
Section: Characterization Of the Complex Stability By Cidmentioning
confidence: 99%
“…Other activation methods, prompt heating of the inlet of the sample solution, for example, might be effective for more quantitative analysis of the dissociation [21]. We are now trying to apply laser spray, developed by Hiraoka et al [22,23], for quantification of binding affinity of c-Myb DBD-dsDNA complexes [24]. This technique might be promising for the quantification of binding affinity of complexes stabilized mainly by hydrogen bonds and/or electrostatic interactions.…”
Section: Characterization Of the Complex Stability By Cidmentioning
confidence: 99%
“…So far, ESI was the only choice for generation of ions directly from aqueous solutions. In a laser spray [31,32], one of the numerous types of ESI sources, ions are generated using an explosive evaporation of effusing aqueous solution by focusing a 10.6 m radiation from a CW CO 2 laser on a tip of the spraying capillary. This atmospheric method of ionization using a continuous laser results in formation of multiplycharged ions, like in normal ESI.…”
Section: Use Of Liquid Water As a Matrix In Ap Ir-maldi Ion Sourcementioning
confidence: 99%
“…῎ 73 ῎ general trend observed for the samples of oligopeptides 44) and proteins. The formation of less highly charged ions for laser spray may be due to the fact that the process of charge enrichment by successive uneven droplet fission is less prominent by laser spray than by electrospray.…”
Section: Development Of New Ionization Methods For Gc/ms and Lc/ms Inmentioning
confidence: 96%
“…13 should be noted. As was already pointed out in our previous paper, 44) selective vaporization of solvent takes place by the laser irradiation resulting in the increase of the sample concentration near the meniscus of the sample solution e#using out from the capillary. The increase of the sample concentration leads to the formation of cluster ions.…”
Section: ῍1mentioning
confidence: 99%
See 1 more Smart Citation