2017
DOI: 10.1177/0974909820170406
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Evaluation of Accuracy of McLaughlin Bennet Trevisi Prescription of Six Commercially Available Orthodontic Metal Brackets: An In vitro Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 0 publications
0
3
3
Order By: Relevance
“…Vinaya S Pai et al 15 in their study found the mean slot width at base for Victory (3M) to be 0.0219 inch and this was similar to the value of the present study. Dissimilar results were found in the study conducted by Daga et al 16 In their study, the slot width at the base of Master Brackets (American Ortho) was 0.0226 inch and this value was greater than the result (0.021130 inch) of the present study. The difference in the mean values of the studies could be due to interlot variation.…”
Section: Discussioncontrasting
confidence: 85%
See 1 more Smart Citation
“…Vinaya S Pai et al 15 in their study found the mean slot width at base for Victory (3M) to be 0.0219 inch and this was similar to the value of the present study. Dissimilar results were found in the study conducted by Daga et al 16 In their study, the slot width at the base of Master Brackets (American Ortho) was 0.0226 inch and this value was greater than the result (0.021130 inch) of the present study. The difference in the mean values of the studies could be due to interlot variation.…”
Section: Discussioncontrasting
confidence: 85%
“…A study done by Karan Tangri et al 14 showed almost similar mean value for slot top width of Leone as the value in their study was 0.0227 inch and the mean slot width at top for Victory (3M) was equivalent to study performed by Vinaya S Pai et al 15 as the value in their study was 0.0222 inch. Daga et al 16 when measured slot width at the top of Master Brackets (American Ortho) bracket slot, the width was found to be 0.0238 inch and this finding was incontrast to the present study. The variation in the mean values of the studies can be due to interlot variation.…”
Section:  Slot Width At Top Of Various Bracket Systemscontrasting
confidence: 44%
“…unit standardization; they are among the researchers who have defined the spectrum of slot and archwire manufacturing features. [ 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 ]…”
Section: Introductionmentioning
confidence: 99%
“…These comprise leaf gauges, pin gauges, digital gauges, a profile projector microscope, a stereomicroscope, an optical microscope, a scanning electron microscope, and a micro-CT scanner. [ 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 ]…”
Section: Introductionmentioning
confidence: 99%
“…Appearance of revolutionary prescriptions as MBT of McLaughlin, Bennett and Trevisi was one of these evolutions. [ 3 ] They aimed to provide the clinician with a new prescription to reach the best goals of treatment. They created even sub-prescriptions for individual variations as the different options regarding the canines’ torque.…”
Section: Introductionmentioning
confidence: 99%