2013
DOI: 10.1016/j.jcms.2012.05.015
|View full text |Cite
|
Sign up to set email alerts
|

“A comparative evaluation between single noncompression titanium miniplate and three dimensional titanium miniplate in treatment of mandibular angle fracture” – A randomized prospective study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
9
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 58 publications
(11 citation statements)
references
References 14 publications
2
9
0
Order By: Relevance
“…This result is consistent with those of other studies, including that of Vineeth et al, which found that patients treated with Champy's technique had limited mouth opening at the 1-month postoperative visit. 16 However, all patients in their study resumed normal mouth opening by the third month.…”
Section: Discussionmentioning
confidence: 87%
See 2 more Smart Citations
“…This result is consistent with those of other studies, including that of Vineeth et al, which found that patients treated with Champy's technique had limited mouth opening at the 1-month postoperative visit. 16 However, all patients in their study resumed normal mouth opening by the third month.…”
Section: Discussionmentioning
confidence: 87%
“…The management strategies associated with the bilateral or multi-fractured mandible differ from those of the isolated angle fracture. 16,30 The complexity involved with the multi-fractured mandible, including establishment of occlusion, stability of segments, and fixation sequencing, can all influence the rate of complications in mandible fracture management. Other limitations of this study include the paucity of follow-up data.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There have been many studies concerned with the fixation method used for mandibular angle fractures. [ 8 9 10 11 12 13 14 15 16 17 18 19 ] Some researchers have advocated the use of two miniplates, one on the external oblique ridge and the other on the lower border of the mandible, to obtain stable fixation based on biomechanical studies. [ 20 21 22 ] However, Ellis and Walker reported high complication rates in cases intraorally fixed with two miniplates.…”
Section: Discussionmentioning
confidence: 99%
“…[1112] Patients of both the groups which reported post-operative malocclusion were relieved by selective grinding and enameloplasty of the dentition. Jules et al ,[13] also reported similar findings of better intrinsic stability, more resistance to fracture fragment mobility in a series of 22 patients of mandibular angle fracture treated with 2.0 mm matrix miniplate.…”
Section: Discussionmentioning
confidence: 99%