2022
DOI: 10.1007/s00216-022-04099-z
|View full text |Cite
|
Sign up to set email alerts
|

A chemiluminescence aptasensor for sensitive detection of alpha-fetoprotein based on hemin@ZIF-67

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 44 publications
0
6
0
Order By: Relevance
“…The powder X-ray diffraction (PXRD) patterns are employed to confirm the crystalline architecture of ZIF-67 (Figure S1B). PXRD spectra exhibit diffraction peaks at 7.4, 10.4, 12.8, and 18.0°c orresponding to (011), (002), (112), and (222) planes, 34 and the PXRD pattern of ZIF-67 is identical to that of simulated ZIF-67, suggesting the successful synthesis of ZIF-67 with good crystallinity. In addition, X-ray photoelectron spectroscopy (XPS) proves the presence of cobalt in ZIF-67 (Figure S1C,D).…”
Section: •−mentioning
confidence: 86%
“…The powder X-ray diffraction (PXRD) patterns are employed to confirm the crystalline architecture of ZIF-67 (Figure S1B). PXRD spectra exhibit diffraction peaks at 7.4, 10.4, 12.8, and 18.0°c orresponding to (011), (002), (112), and (222) planes, 34 and the PXRD pattern of ZIF-67 is identical to that of simulated ZIF-67, suggesting the successful synthesis of ZIF-67 with good crystallinity. In addition, X-ray photoelectron spectroscopy (XPS) proves the presence of cobalt in ZIF-67 (Figure S1C,D).…”
Section: •−mentioning
confidence: 86%
“…The detection limit of the method for VEGF is 50 pM, and the concentration ranges from 0 to 25 nM ( Li W. et al, 2015 ). Wang J. et al (2022) detected AFP based on the CL system of hemin@ZIF-67–H 2 O 2 -NaOH, achieving a detection limit of 0.13 ng/mL. In a study conducted by Han R. et al (2020) , a sensing platform based on the luminol–H 2 O 2 –metal organic framework (MOF) system was constructed for AFP detection.…”
Section: Optical Aptasensorsmentioning
confidence: 99%
“…Under the optimal conditions, the CL signal had a linear relationship with the concentration of AFP, in the range of 0.1 ng/L to 30 μg/L; the LOD was 77 pg/L. Wang et al [ 70 ] used hemin@ZIF-67 composites to construct a chemiluminescence (CL) aptasensor for AFP detection. A hemin/ZIF-67 composite was prepared via covalent bonding between the carboxyl groups of hemins and cobalt ion of ZIF-67.…”
Section: Afp Detection Based On Optical Aptamer Biosensormentioning
confidence: 99%