2019
DOI: 10.1002/asia.201900739
|View full text |Cite
|
Sign up to set email alerts
|

A CdII‐Based Metal‐Organic Framework with pcu Topology as Turn‐On Fluorescent Sensor for Al3+

Abstract: An ew metal-organic framework (MOF) {[Cd 2 (bbib) 2 (ndc) 2 ]·2DMF} n (JXUST-1)( bbib = 1,3-bis(benzimidazolyl)benzene, H 2 ndc = 1,4-naphthalenedicarboxylic acid, DMF = N,N-dimethylformamide) has been solvothermally synthesizeda nd characterizedb ys ingle-crystal X-ray diffraction, PXRD, TGA, IR and elementala nalysis. JXUST-1 exhibits at hree-dimensional 6-connected pcu topologyw ith aS chläfli symbol {4 12 .6 3 }c onstructed by [Cd 2 (CO 2 ) 3 ]s econdary build-ing units. Fluorescence studies show that this… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 61 publications
(8 citation statements)
references
References 65 publications
(20 reference statements)
0
8
0
Order By: Relevance
“…A novel three‐dimensional MOF {[Cd 2 (bbib) 2 (ndc) 2 ] ⋅ 2DMF} n (JXUST‐1) with pcu topology was solvothermally synthesised and could be utilised as an efficient, reusable fluorescence turn‐on probe for the detection of Al 3+ , with low detection limits. The probe was found to exhibit good solvent and thermal stabilities [58] …”
Section: Mof Sensors Based On Optical Propertiesmentioning
confidence: 99%
“…A novel three‐dimensional MOF {[Cd 2 (bbib) 2 (ndc) 2 ] ⋅ 2DMF} n (JXUST‐1) with pcu topology was solvothermally synthesised and could be utilised as an efficient, reusable fluorescence turn‐on probe for the detection of Al 3+ , with low detection limits. The probe was found to exhibit good solvent and thermal stabilities [58] …”
Section: Mof Sensors Based On Optical Propertiesmentioning
confidence: 99%
“…• Adaptable: User-friendly graphical user interface (GUI) and automated dataflow between multiple module functions allow easy adaptation of the workflow to specific user requirements; Considering the variety of MOF materials and possible attained properties, multiple options for such workflow developments are possible. In the present study, we focus on the primitive cubic (PCU) topology of MOFs (O'Keeffe and Yaghi, 2012) (Figure 1) that is a widely used topology found in fabricated MOF materials (Li et al, 2007;Luo et al, 2017;Wei et al, 2019;Xing et al, 2019;Yao et al, 2019). The PCU topology features the network that describes the MOF-2 family, which has paddle-wheel nodes, such as Zn 2 (CO 2 ) 4 and Cu 2 (CO 2 ) 4 , connected by linkers (Li et al, 1998;Xing et al, 2019;Goldman et al, 2020;Qiao et al, 2020;Yazdanparast et al, 2020) and the MOF-5 family with octahedral nodes, such as Zn 4 (O)O 12 C 6 (Li et al, 1999;Schoedel et al, 2016).…”
Section: Introductionmentioning
confidence: 99%
“…The PCU topology features the network that describes the MOF-2 family, which has paddle-wheel nodes, such as Zn 2 (CO 2 ) 4 and Cu 2 (CO 2 ) 4 , connected by linkers (Li et al, 1998;Xing et al, 2019;Goldman et al, 2020;Qiao et al, 2020;Yazdanparast et al, 2020) and the MOF-5 family with octahedral nodes, such as Zn 4 (O)O 12 C 6 (Li et al, 1999;Schoedel et al, 2016). It can be formed also from SBUs based on Mg, Cd, Pb, or rare earth metals (Bhattacharya et al, 2014;Luo et al, 2017;Lin et al, 2018;Yao et al, 2019). In addition, MOF films grown using a layer-by-layer technique on the pre-functionalized surfaces, e.g., surface-anchored MOFs (SURMOFs) (Liu et al, 2012;Zhuang et al, 2016), using Cu 2 (CO 2 ) 4 and Zn 2 (CO 2 ) 4 SBUs are often assembled in PCU-type networks.…”
Section: Introductionmentioning
confidence: 99%
“…[33][34][35][36] Most CPs can only be used to detect a single substance, so designing and synthesizing CPs with multifunctional fluorescent recognition sites is an effective method to detect various pollutants. [37][38][39] In…”
Section: Introductionmentioning
confidence: 99%
“…Compared to some instrumental analysis methods, coordination polymer, as a new fluorescent probe, has the characteristics of low cost, simple detection and high sensitivity [33–36] . Most CPs can only be used to detect a single substance, so designing and synthesizing CPs with multifunctional fluorescent recognition sites is an effective method to detect various pollutants [37–39] …”
Section: Introductionmentioning
confidence: 99%