2019
DOI: 10.1016/j.chemosphere.2019.02.135
|View full text |Cite
|
Sign up to set email alerts
|

A case of anisotropic exchange of non-polar chemicals with absorption-based passive samplers in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…Passive sampling represents a cost-efficient technique, which can achieve low limits of quantification (LOQ) for some compounds with less labour and time compared to the methods discussed above that rely on the post-sampling extraction of compounds from water samples (Bundschuh et al, 2014;Taylor et al, 2020). Moreover, passive samplers only sample the compounds in the dissolved phase and degradation of compounds in the sampler has not been reported, though fouling of the sorbent phase might have an effect (Allan and Jenssen, 2019;Schäfer et al, 2008). Therefore, passive sampling methods have gained popularity for sampling toxicants such as pesticides in streams and have been recommended for use in governmental routine monitoring (Brack et al, 2017;Moschet et al, 2014;Szöcs et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…Passive sampling represents a cost-efficient technique, which can achieve low limits of quantification (LOQ) for some compounds with less labour and time compared to the methods discussed above that rely on the post-sampling extraction of compounds from water samples (Bundschuh et al, 2014;Taylor et al, 2020). Moreover, passive samplers only sample the compounds in the dissolved phase and degradation of compounds in the sampler has not been reported, though fouling of the sorbent phase might have an effect (Allan and Jenssen, 2019;Schäfer et al, 2008). Therefore, passive sampling methods have gained popularity for sampling toxicants such as pesticides in streams and have been recommended for use in governmental routine monitoring (Brack et al, 2017;Moschet et al, 2014;Szöcs et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…The general cleanup and GPC procedures have been described elsewhere 15,19 . Analysis for PRCs and OCs was performed on an Agilent 7890A gas chromatograph coupled to an Agilent 5975c inert XL EI/CI quadrupole mass spectrometer operated in single-ion monitoring mode (SIM) with electron impact ionisation (70 keV) 20,21 . Analyte separation was on a DB-5MS column (30 m, 0.25 mm inside diameter and 0.25 µm film thickness; Agilent JW Scientific) with a 1 µL pulsed split-less injection (pulse pressure 20 psi for 1.2 min and injector temperature of 300 °C).…”
Section: Methodsmentioning
confidence: 99%