A capillary electrophoresis system with dual capacitively coupled contactless conductivity detection and electrospray ionization tandem mass spectrometry

Abstract: A commercial system that is comprised of a CE coupled to an ESI triple quadrupole mass spectrometer was equipped with two capacitively coupled contactless conductivity detectors (C(4) Ds). The first C(4) D was positioned inside the original cartridge, and the second C(4) D was positioned as close as possible to the ESI probe entrance by using a 3D-printed support. The C(4) Ds electropherograms were matched to the ESI-MS electropherogram by correcting their timescales by the factor LT /LD , where LT and LD are … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 26 publications
0
14
0
Order By: Relevance
“…Because the detectors are 10 cm apart from each other, species reach each detector at different time. Thus, just for comparison purpose, the migration times of all analytes in CE–UV were adjusted as described elsewhere (Fig. ).…”
Section: Resultsmentioning
confidence: 99%
“…Because the detectors are 10 cm apart from each other, species reach each detector at different time. Thus, just for comparison purpose, the migration times of all analytes in CE–UV were adjusted as described elsewhere (Fig. ).…”
Section: Resultsmentioning
confidence: 99%
“…The appearance of their first oscillometric detector in 1998 [40] was followed by the second generation with hardware improvement in 2002 [42]. This group then moved toward the direction of open C 4 D [43,44] and 3Dbased CE-C 4 D design [45]. All these developments from both directions (i.e., purpose-made C 4 D and open C 4 D) aim at affordable analytical instrumentation for the population to the authors' viewpoint.…”
Section: Development Of Our Different Purpose-made C 4 D Designsmentioning
confidence: 99%
“…Simultaneous detection of separated zones by two or even more unique detectors usually offers higher characterization power/improved analytical information. New detection systems combining C 4 D with mass spectrometry and C 4 D with mass spectrometry and amperometry were described recently. Data processing for CE‐C 4 D is usually carried out automatically on commercial CE instruments.…”
Section: Applications Of Ce‐c4dmentioning
confidence: 99%
“…They found the two detectors to be complementary in that the C 4 D allowed the quantification of inorganic ions which were not accessible with the MS system while organic ions showed better sensitivity with the latter. Francisco and do Lago also combined C 4 D with mass‐spectrometric detection as an aid in optimizing the operating conditions. Müller et al.…”
Section: Fundamental Characterization and Instrumental Developmentsmentioning
confidence: 99%