2011
DOI: 10.1109/tim.2011.2159316
|View full text |Cite
|
Sign up to set email alerts
|

A Bus-Based Smart Myoelectric Electrode/Amplifier—System Requirements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 34 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…Three studies reported that the classification accuracies obtained from a set of multiple time domain features dramatically decrease when the sampling rate is lower than 200 Hz [ 15 ], 400 Hz [ 16 ], or 600 Hz [ 17 ]. In contrast, the other study [ 18 ] reported that reducing the sampling rate does not degrade the classification performance of the similar feature set. This study also examined the performance of myoelectric control as the resolution of analog to digital (A/D) conversion is decreased, and suggested that the resolution of the A/D conversion can be reduced to 8-bit while maintaining or even improving classification performance [ 18 ].…”
Section: Introductionmentioning
confidence: 85%
See 3 more Smart Citations
“…Three studies reported that the classification accuracies obtained from a set of multiple time domain features dramatically decrease when the sampling rate is lower than 200 Hz [ 15 ], 400 Hz [ 16 ], or 600 Hz [ 17 ]. In contrast, the other study [ 18 ] reported that reducing the sampling rate does not degrade the classification performance of the similar feature set. This study also examined the performance of myoelectric control as the resolution of analog to digital (A/D) conversion is decreased, and suggested that the resolution of the A/D conversion can be reduced to 8-bit while maintaining or even improving classification performance [ 18 ].…”
Section: Introductionmentioning
confidence: 85%
“…In contrast, the other study [ 18 ] reported that reducing the sampling rate does not degrade the classification performance of the similar feature set. This study also examined the performance of myoelectric control as the resolution of analog to digital (A/D) conversion is decreased, and suggested that the resolution of the A/D conversion can be reduced to 8-bit while maintaining or even improving classification performance [ 18 ]. Thus, with the growing adoption of lower-bandwidth sensor systems, a better investigation of how the classification performance of EMG feature extraction methods is affected by lower sampling rates is warranted.…”
Section: Introductionmentioning
confidence: 85%
See 2 more Smart Citations
“…A subject performing the target familiarization block by controlling a cursor on the screen using myoelectric signals sensed by the UNB Smart Electrode System, which is placed on the subjects forearm, to acquire a target movements while providing a comfortable setting during scheduled breaks between testing blocks. A UNB Smart Electrode System [29] was placed on the subject's right forearm ( Fig.2) and the real-time myoelectric signals extracted from muscles contractions were monitored using the Acquisition and Control Environment (ACE) software package [30] developed using MATLAB (Release 2007, The MathWorks, Inc., Natick, Massachusetts, United States).…”
Section: Fig 2 Experimental Setupmentioning
confidence: 99%