2002
DOI: 10.1002/mrc.1097
|View full text |Cite
|
Sign up to set email alerts
|

A broadband ADEQUATE pulse sequence using chirp pulses

Abstract: Recently, we have introduced the ADEQUATE pulse sequence as a sensitive method to observe 13 C, 13 C correlations in natural products. This kind of experiment suffers from offset-dependent effects of the 180• ( 13 C) pulses. Here we describe an application of smoothed chirp pulses in the ADEQUATE pulse sequence which allows 13 C, 13 C correlations to be run without any offset dependences. This experiment is called chirp ADEQUATE and was applied to d-valerolactone and cholesteryl acetate. This modification will… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
67
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 64 publications
(67 citation statements)
references
References 36 publications
0
67
0
Order By: Relevance
“…Contiguous non-protonated carbon resonances can be spanned by either a variant of the HMBC [19] experiment or an experiment such as 1,n-ADEQUATE. [16] The structure of strychnine shown below summarizes the carbon-carbon bond connectivities derived from HSQC-ADEQUATE data. Solid lines in either red or blue indicate adjacent protonated carbon pairs.…”
Section: Resultsmentioning
confidence: 99%
“…Contiguous non-protonated carbon resonances can be spanned by either a variant of the HMBC [19] experiment or an experiment such as 1,n-ADEQUATE. [16] The structure of strychnine shown below summarizes the carbon-carbon bond connectivities derived from HSQC-ADEQUATE data. Solid lines in either red or blue indicate adjacent protonated carbon pairs.…”
Section: Resultsmentioning
confidence: 99%
“…We use, wherever possible, broad-band excitation and inversion pulses 17,18 -an approach proposed previously for inversion pulses. 19 The determination of 1 J CC values from the nonrefocused INADEQUATE spectra is trivial because of large separation of the two components of the one-bond antiphase doublets. Prior to peak picking, it maybe beneficial to add or subtract the two spectra, providing both contain one-bond cross peaks with sufficient intensity.…”
Section: Resultsmentioning
confidence: 99%
“…The performance of these pulses is compared with the composite adiabatic pulse scheme [19] implemented as a smoothed Chirp pulse [44,45] in standard Bruker software .…”
Section: Burbop Compared To Refocusing With Pp Pulsesmentioning
confidence: 99%
“…The best broadband refocusing performance available in the standard Bruker pulse library satisfying the required conservative pulse power limits is obtained using the pulse designated Chirp80 [45]. This pulse is constructed from three adiabatic inversion pulses with pulse lengths in the ratio 1:2:1 [19].…”
Section: Three Adiabatic Inversion Pulsesmentioning