2021
DOI: 10.1007/s10967-021-07778-w
|View full text |Cite
|
Sign up to set email alerts
|

A brief radiological survey and associated occupational exposure to radiation in an open pit slate mine in Kashan, Iran

Abstract: A comprehensive radiological survey was carried out in an open-cut slate stone quarry. The activity of 226Ra, 228Ra and 40 K in the ore samples were measured as 38 ± 5, 41 ± 6 and 869 ± 52 Bq kg1, respectively. Outdoor radon and indoor radon concentrations were measured from 37 ± 7 to 193 ± 11 Bq m−3 (77 ± 8 Bq m−3), and 49 ± 6 to 253 ± 23 Bq m−3 (131 ± 13 Bq m−3), respectively. The average indoor and outdoor gamma dose were measured as 116 and 84 nSv h− 1, respectively. The annual effective doses were estimat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…The tracks can then be counted and analyzed to determine the radiation dose. Further details are extensively discussed in our previous publications [ [19] , [20] , [21] , [22] ].
Fig.
…”
Section: Methodsmentioning
confidence: 99%
“…The tracks can then be counted and analyzed to determine the radiation dose. Further details are extensively discussed in our previous publications [ [19] , [20] , [21] , [22] ].
Fig.
…”
Section: Methodsmentioning
confidence: 99%
“…Radon measurement was divided into two different methods of passive and active monitoring. The methodology of these measurements could be found in the previously published papers [16][17][18][19].…”
Section: Radon Monitoringmentioning
confidence: 99%
“…By taking into consideration the aforementioned criteria, a different range of ventilation rates from 0.3 to 4.3 h −1 (also reported by Zhou et al 8 and Agarwal et al 14 ) was considered and assessed in the current study. The radon source term as a key input parameter in the CFD software (ANSYS Fluent 2020 R1 based on the FVM) has also been measured by an accumulation chamber technique for samples of cement (comprehensively described in Kocsis et al 17 and Shahrokhi et al 18 ) before the simulations took into account the room geometry. To validate the simulation results, two pairs of common radon monitoring methods, namely NRPB and Raduet (as passive methods based on CR-39) as well as AlphaGUARD and RAD7 (as active methods), were also used to measure the indoor radon concentration under the aforementioned scenarios at various locations throughout the room.…”
Section: Introductionmentioning