2021
DOI: 10.1016/j.snb.2021.129972
|View full text |Cite
|
Sign up to set email alerts
|

A bistable, multiport valve enables microformulators creating microclinical analyzers that reveal aberrant glutamate metabolism in astrocytes derived from a tuberous sclerosis patient

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 51 publications
1
9
0
Order By: Relevance
“…The use of valves is critical in the calibration of these biosensors. 125 In this paper, an automated multipumps system was used for in situ calibration of an electrochemical glutamate sensor. The sensor was calibrated every four hours during the 76-hour experiment.…”
Section: Biochemical Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of valves is critical in the calibration of these biosensors. 125 In this paper, an automated multipumps system was used for in situ calibration of an electrochemical glutamate sensor. The sensor was calibrated every four hours during the 76-hour experiment.…”
Section: Biochemical Parametersmentioning
confidence: 99%
“…Some recently developed on-chip valves are easier to use. 125,149,150 The on-chip valves are actuated by rolling the roller and pressing the PC bar with through hole. These technologies offer the possibility of developing fully automated, integrated, and miniaturized MPSs, which could provide a better understanding of disease mechanisms and accelerate the development of drugs in the future.…”
Section: Easy To Usementioning
confidence: 99%
“…A replicate set of valves and pumps aspirates fluid out of the wells; coordinating the aspiration and dispensing enables changing the drug concentration in each well. A controller is programmed to generate a defined drug exposure profile over a set time interval (24-hour) cycle using predefined intervals of drug/media refresh to achieve the desired time-dependent change in drug concentrations [ 19 ]. Each well is individually addressable, and 1 or 2 compounds can be administered simultaneously, each with its own PK profile.…”
Section: Resultsmentioning
confidence: 99%
“…The design, fabrication, and performance validation of the rotary planar valves and rotary planar peristaltic micropumps that comprise the Microformulator have been previously described [ 19 ] and were built using technologies developed at the VIIBRE. Other embodiments of the Microformulator and its pumps and valves have been described elsewhere [ 37 , 38 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation