A biosensor for the determination of high density lipoprotein cholesterol employing combined surfactant-derived selectivity and sensitivity enhancements

Abstract: A biosensor for the determination of high density lipoprotein cholesterol employing combined surfactant-derived selectivity and sensitivity enhancements. Analytical Methods, 6. pp. 3975-3981. ISSN 1759-9660 Available from: http://eprints.uwe.ac.uk/23377We recommend you cite the published version. The publisher's URL is: http://dx.doi.org/10.1039/C3AY42262C Refereed: YesPublished online first 7 Mar 2014 Disclaimer UWE has obtained warranties from all depositors as to their title in the material deposited and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 41 publications
0
2
0
Order By: Relevance
“…The cholesterol sample comprises phosphate buffered saline (PBS)/Triton solution added onto 100 U/ml enzyme cholesterol oxidase (ChOx). This method measures free cholesterol rather the ratio of high‐ to low‐density lipoprotein cholesterol [34]. The measurements are taken after a settling time of 400 s, to allow the current from the cell to stabilise to a steady state, followed by a reaction time of 180 s. Subsequently, such timing defines the bandwidth of the sensor, which is not considered here to be a key design parameter, and thus a bandwidth of >1 Hz is deemed to be sufficient.…”
Section: Methodsmentioning
confidence: 99%
“…The cholesterol sample comprises phosphate buffered saline (PBS)/Triton solution added onto 100 U/ml enzyme cholesterol oxidase (ChOx). This method measures free cholesterol rather the ratio of high‐ to low‐density lipoprotein cholesterol [34]. The measurements are taken after a settling time of 400 s, to allow the current from the cell to stabilise to a steady state, followed by a reaction time of 180 s. Subsequently, such timing defines the bandwidth of the sensor, which is not considered here to be a key design parameter, and thus a bandwidth of >1 Hz is deemed to be sufficient.…”
Section: Methodsmentioning
confidence: 99%
“…The levels of triglycerides, HDL-C, and fasting blood glucose were measured using enzymatic methods on Lipid Biosensor (TamilNadu, India). 21…”
Section: Biochemical Analysismentioning