2010
DOI: 10.1016/j.arthro.2010.02.018
|View full text |Cite
|
Sign up to set email alerts
|

A Biomechanical Comparison of the EndoButton CL Using Transtibial Drilling and EndoButton Direct Using Anteromedial Arthroscopic Drilling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 18 publications
0
9
0
Order By: Relevance
“…In a porcine biomechanical study, Ahmad et al 36 found that suspensory cortical femoral fixation had higher ultimate failure load and less graft slippage than interference screws. Milano et al 37 and Miller et al 38 also showed that extracortical fixation has a mean load to failure of 700–1150 N. The failure load for interference screws in soft-tissue grafts is close to 450 N, which was termed by Noyes et al 39 as the physiological load that the knee has to withstand.…”
Section: Discussionmentioning
confidence: 98%
“…In a porcine biomechanical study, Ahmad et al 36 found that suspensory cortical femoral fixation had higher ultimate failure load and less graft slippage than interference screws. Milano et al 37 and Miller et al 38 also showed that extracortical fixation has a mean load to failure of 700–1150 N. The failure load for interference screws in soft-tissue grafts is close to 450 N, which was termed by Noyes et al 39 as the physiological load that the knee has to withstand.…”
Section: Discussionmentioning
confidence: 98%
“…Ahmad CS et al found in a porcine biomechanical study that suspensory cortical femoral fixation had a higher ultimate failure load of 864 N and less graft slippage as compared to interference screw with a failure load of 539 N [77]. Various other authors have also shown that extracortical fixation has a mean load to failure of 700 N to 1150 N during biomechanical testing [78,79]. The failure load for the interference screw is close to 450 N, which is what Noyes terms the physiological load that the knee has to withstand [80].…”
Section: Discussionmentioning
confidence: 99%
“…Since secure fixation of a ligament is directly associated with postoperative outcomes, various types of fixtures are used in clinical practice [1]. Various fixtures are used in anterior cruciate ligament (ACL) reconstruction, including interference screws, post screws, double spike plate (DSP) screws and double staples [2][3][4][5][6], and their mechanical properties have been studied [7]. The Endo-Button, a suspensory cortical button, is widely used because it allows for easy and relatively strong fixation [8,9].…”
Section: Introductionmentioning
confidence: 99%