2019
DOI: 10.1109/tbcas.2019.2936327
|View full text |Cite
|
Sign up to set email alerts
|

A 9.2-g Fully-Flexible Wireless Ambulatory EEG Monitoring and Diagnostics Headband With Analog Motion Artifact Detection and Compensation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(12 citation statements)
references
References 19 publications
0
12
0
Order By: Relevance
“…where Z path R Body + Z ESI + Z E . This formula emphasizes the impact of Z ESI variation, which directly changes the amplitude of the output signal due to gain distortion (Song et al, 2014;Dabbaghian et al, 2019).…”
Section: Understanding Of Electroencephalography Motion Artifactmentioning
confidence: 99%
See 2 more Smart Citations
“…where Z path R Body + Z ESI + Z E . This formula emphasizes the impact of Z ESI variation, which directly changes the amplitude of the output signal due to gain distortion (Song et al, 2014;Dabbaghian et al, 2019).…”
Section: Understanding Of Electroencephalography Motion Artifactmentioning
confidence: 99%
“…To attain low cutoff frequency, a GΩ range resistance is required. In CMOS applications, resistor-emulating (Dätwyler, 2021), (E) reverse-curve arch-shaped dry electrode (Lee et al, 2015), (F) bristle-type electrode (Grozea et al, 2011), (G) microneedle electrode (Ren et al, 2020a)), (H) semi-wet electrode (Wang et al, 2016), and (I) flexible EEG system (Dabbaghian et al, 2019). circuits such as pseudo-resistors, switched-capacitor resistors, and switched-resistor resistors are adopted (Xu et al, 2017).…”
Section: Active Electrode and Analog Circuitsmentioning
confidence: 99%
See 1 more Smart Citation
“…The amplitude of the recorded artifact spike is determined by several factors such as the distance between the recording and the stimulation sites, the gain of the amplifier, and the electrode impedance (Johnson et al, 2017;Pazhouhandeh et al, 2018;Jeon et al, 2019;Uehlin et al, 2020). The artifact is typically hundreds of millivolts in amplitude, and 10 to 100 times higher than the amplitude of the recorded neural signals (Dabbaghian et al, 2019;Lee and Je, 2020). Several stimulation artifact cancelation techniques have been reported previously.…”
Section: Key Issues In Neural Recording and Stimulation Circuits Stimulation Induced Artifact In The Closed-loop Systemmentioning
confidence: 99%
“…Benefiting from the rapid development of the sensor technologies and the miniaturization of the electronics, the wearable and implantable electronic devices have been widely used in biomedical research Yang et al (2019); Juteau and Gosselin (2020), motion detection Le et al (2019); Dabbaghian et al (2019) and health monitoring Ding et al (2021); Lee et al, 2020b. In such scenarios, the wireless sensor nodes (WSNs) are in charge of monitoring the physical parameters and transmitting the digitized data. It is highly demanded to prolong the usage time of the WSNs while subjecting to small-volume batteries.…”
Section: Introductionmentioning
confidence: 99%