1999
DOI: 10.1109/10.804576
|View full text |Cite
|
Sign up to set email alerts
|

A 2 1/4-turn spiral antenna for catheter cardiac ablation

Abstract: To investigate the delivery of microwave energy by a catheter positioned inside the heart for ablating small abnormal regions producing cardiac arrhythmias, a 2 1/4-turn spiral catheter-based microwave antenna applicator has been developed. The antenna consists of the center conductor with continuous insulating material extending from the coaxial feed cable formed into a spiral antenna. The insulator completely isolates the center conductor from tissue. Phantom experiments were performed on homogeneous tissue … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2001
2001
2021
2021

Publication Types

Select...
4
4
2

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Notably, looped designs operating in the axial mode have been described for cardiac ablation, while helices have been proposed for microwave-assisted angioplasty 49, 63. Single and multi-loop designs have also been tested for microwave ablation in the liver 64…”
Section: Microwave Ablation Technologymentioning
confidence: 99%
“…Notably, looped designs operating in the axial mode have been described for cardiac ablation, while helices have been proposed for microwave-assisted angioplasty 49, 63. Single and multi-loop designs have also been tested for microwave ablation in the liver 64…”
Section: Microwave Ablation Technologymentioning
confidence: 99%
“…6,7,10,12,[17][18][19][20]23,27,33,35,39 In addition, studies have been conducted on the effects of implantable chips placed on the retina, cardiac muscle, and other structures within the body. 4,8,15,16,26,30,34,37 However, much less has been done on the consequences of wirelessly powering devices within the skull 14,31 . In this work, a 2-D numerical model with approximations to 3D was developed and implemented to provide an analysis of the SAR values and temperature changes in the cortical tissue surrounding the implanted and electromagnetically-excited BMI chip(s).…”
Section: Introductionmentioning
confidence: 98%
“…Thus, these two currents will excite fields that constructively interfere along the axis of the loop and cancel outside the loop. For a loop positioned on a planar tissue surface, this modest focusing yields an enhanced electric field and, hence, increased power deposition at depth within the tissue 37,38 .…”
Section: Wide Aperture Catheter Antennasmentioning
confidence: 99%