2014
DOI: 10.1109/tps.2014.2317572
|View full text |Cite
|
Sign up to set email alerts
|

A 10 GW Tesla-Driven Blumlein Pulsed Power Generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 15 publications
0
13
0
1
Order By: Relevance
“…The existing 10-GW-Tesla-Blumlein PFL generator has so far been operated with a series-connected 30 resistive load [1]. As PSPICE simulation results show (Fig.…”
Section: Adapting the Blumlein Pfl Output For Operation With A Bimentioning
confidence: 99%
See 2 more Smart Citations
“…The existing 10-GW-Tesla-Blumlein PFL generator has so far been operated with a series-connected 30 resistive load [1]. As PSPICE simulation results show (Fig.…”
Section: Adapting the Blumlein Pfl Output For Operation With A Bimentioning
confidence: 99%
“…The first of these, mounted in the outer wall of the Blumlein-PFL, was fully described and its sensitivity k 1 provided elsewhere [1]. The second and third probes, having sensitivities k 2 ≈ 0.3 ps and k 3 ≈ 0.2 ps, are made from 18-GHz female-female N-type adaptors and placed, respectively, after the 130 resistor at the Blumlein-PFL transmission line output and in the wall of the bipolar former 50-output transmission line.…”
Section: Diagnosticsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although used initially for the high-voltage testing of domestic and industrial power insulation and switchgear, in recent years they have become a vital requirement in many research areas, particularly those involving particle and plasma physics, as well as high power systems that involve the generation of microwave and X-ray radiation. Despite the original experiments being performed by Nikola Tesla (Lomas, 2000) well over a hundred years ago, with the typical and very spectacular results evident in Figure 1, important new applications still continue to arise in technically active countries worldwide e.g (Peng, Liu, Song, & Su, 2011;Novac, Wang, Smith, & Senior, 2014;Su et al, 2016). Tesla transformers are produced in several different constructional forms and they can be classified in a number of ways depending on the sometimes competing output requirements of extremely high voltage or high average power.…”
Section: Introductionmentioning
confidence: 99%
“…(TLs) and will demonstrate that use of 'standard' V-dot probes, simply made from off-the-shelf SMA-or N-type connectors and adaptors [9][10][11], represents a practical solution which potentially offers a simpler alternative to most of the design challenges associated with V-dot probes. The results of the present work are of particular interest for anyone in the domain aiming to obtain results straightforwardly, without losing precious time in developing a new V-dot probe design.…”
mentioning
confidence: 99%