Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 7 publications
0
16
0
Order By: Relevance
“…Organo-gadolinium compounds soluble in classical monomers (MMA and styrene): (a) General formula of gadolinium phenyl-carboxylate; [28], (b) gadolinium isopropoxide; [26] and (c) gadolinium phenylpropionate [32]. Britvich et al [24] reported as well the use of neutron absorbers for plastic scintillators, loading either in the form of o-carborane (4%), boric acid [25] (3%) or 6 LiF (0.1%). Scintillation yields were measured to be 8600, 6200 and 9400 ph/MeV respectively.…”
Section: Lithium Boron Cadmium and Gadolinium Loadings For Thermal mentioning
confidence: 99%
“…Organo-gadolinium compounds soluble in classical monomers (MMA and styrene): (a) General formula of gadolinium phenyl-carboxylate; [28], (b) gadolinium isopropoxide; [26] and (c) gadolinium phenylpropionate [32]. Britvich et al [24] reported as well the use of neutron absorbers for plastic scintillators, loading either in the form of o-carborane (4%), boric acid [25] (3%) or 6 LiF (0.1%). Scintillation yields were measured to be 8600, 6200 and 9400 ph/MeV respectively.…”
Section: Lithium Boron Cadmium and Gadolinium Loadings For Thermal mentioning
confidence: 99%
“…Fluors for the new scintillator composition, BASF143E polystyrene + 1.5% PTP + 0.04% POPOP were selected [12,13] Wave length, nm Emission / Absorption, a.u. Shashlyk module (at the entrance to the photo-detector) becomes N γ ≈ 60 photons per 1 MeV of the incident photon energy.…”
Section: Psm115 σ=117%mentioning
confidence: 99%
“…Plastic scintillators enriched by 6 Li or 10 B [18,19] may be used as an active medium for the detection of decelerated neutrons. Inside a boroncontaining plastic scintillator, the registration of charged products of the reaction 10 Bðn; aÞ 7 Li takes place.…”
Section: Selection Of the Active Mediummentioning
confidence: 99%
“…The light output of the scintillator is about 56-60% of that for anthracene, the luminescence maximum wavelength is about l max ¼ 420 nm, and it contains K ¼ 2-3% by weight of natural boron [19]. It is known that the light output of a-particle-induced scintillations is considerably lower than that from b-particles of corresponding energy.…”
Section: Selection Of the Active Mediummentioning
confidence: 99%