Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…An exception is the spontaneous emission probabilities A mn ; the corre sponding data in the literature are rather ambiguous [2,3,[14][15][16]. In view of the aforesaid, one must either measure A mn with a high accuracy or apply techniques that do not involve A mn in order to reduce the error in determining .…”
Section: Measurement Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…An exception is the spontaneous emission probabilities A mn ; the corre sponding data in the literature are rather ambiguous [2,3,[14][15][16]. In view of the aforesaid, one must either measure A mn with a high accuracy or apply techniques that do not involve A mn in order to reduce the error in determining .…”
Section: Measurement Techniquementioning
confidence: 99%
“…The exponent n in (1) depends on the mechanism of interaction between colliding molecules; for the 10 0 0-00 0 1 transition lines, it ranges from 0.5 to 1 [3,4,8,9]. From this point on, the temperature T is given in kelvins.…”
Section: Introductionmentioning
confidence: 99%
“…Knowledge of the spectroscopic parameters of the appropriate lines of the CO 2 molecule and their temperature dependences is essential in order to use optical methods to determine the CO 2 concentration and temperature in the atmosphere and heated gaseous fuel-combustion products and to calculate the characteristics of powerful industrial CO 2 lasers [1][2][3][4]. Experimental and theoretical results for collisional broadening of molecular spectral lines including those of CO 2 were published [5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…The exponent n depends on the mechanism through which the colliding molecules interact and for lines of the 10 0 0-00 0 1 transition has values lying within the range 0.5-1.0 according to various sources [2,3,8,9]. Δν L is usually determined directly, by measuring the shape of the absorption line profile using a tuneable radiation source, or by measuring the unsaturated absorption coefficient at a single, e.g., central, absorption line frequency at a pressure which produces a collisionally broadened line profile.…”
mentioning
confidence: 99%
“…(2) have been measured for CO 2 with fairly high accuracy. The exception is the spontaneous emission probability A mn , for which the published values have a rather large uncertainty [2,[11][12][13]. Given this, in order to increase the accuracy of the determination of γ CO 2 −CO 2 , it is either necessary to measure A mn or to propose a method that does not use A mn .…”
mentioning
confidence: 99%