2003
DOI: 10.1097/00000421-200306000-00027
|View full text |Cite
|
Sign up to set email alerts
|

Untitled

Abstract: The primary objective of the present study is to demonstrate that a unique computed tomography (CT)-linear accelerator combination can be used to reduce uncertainties caused by organ motion and setup inaccuracy. The acceptance, commissioning, and clinical implementation of a sliding gantry CT scanner installed in an existing linear accelerator room are reported in this paper. A Siemens CT scanner was installed directly opposite to an existing accelerator. The scanner is movable on a pair of horizontal rails mo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2004
2004
2010
2010

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Ultrasound [2530] and in-room CT scanners [3133] were the first volumetric imaging strategies used in the treatment room (e.g., Primatrom; Siemens, Concord, CA and ExaCT; Varian Medical Systems, Palo Alto, CA) [34, 35]. Helical MV CT scans can be obtained using an integrated treatment unit (Tomotherapy, Madison, WI) that allows the MV treatment beam to rotate around the patient while the couch moves, creating volumetric MV images [3640].…”
Section: Rt Processmentioning
confidence: 99%
“…Ultrasound [2530] and in-room CT scanners [3133] were the first volumetric imaging strategies used in the treatment room (e.g., Primatrom; Siemens, Concord, CA and ExaCT; Varian Medical Systems, Palo Alto, CA) [34, 35]. Helical MV CT scans can be obtained using an integrated treatment unit (Tomotherapy, Madison, WI) that allows the MV treatment beam to rotate around the patient while the couch moves, creating volumetric MV images [3640].…”
Section: Rt Processmentioning
confidence: 99%
“…Various approaches to image-guided radiation therapy (IGRT) have been proposed. Amongst these are implanted radio opaque markers (Balter et al 1995, Litzenberg et al 2002, Sandler et al 1993, implanted magnetic markers (Lennernas 1997, Lennernas et al 1999, Lennernas and Nilsson 1995, ultrasound systems (Bouchet et al 2001, Lattanzi et al 1999, Morr et al 2002, Tome et al 2002, CT/LINAC (Cheng et al 2003, Court et al 2003, MVCT (Mackie et al 1993, Swindell 1983, MV cone-beam CT (Ford et al 2002, Midgley et al 1998, Mosleh-Shirazi et al 1998, Pouliot et al 2005, Seppi et al 2003 and kV cone-beam CT (Berbeco et al 2004, Jaffray et al 1999, 2002, Jaffray and Siewerdsen 2000. Each system has advantages and disadvantages and no one method has emerged as clearly superior.…”
Section: Introductionmentioning
confidence: 99%