2001
DOI: 10.1023/a:1011326004528
|View full text |Cite
|
Sign up to set email alerts
|

Untitled

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
0
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 1 publication
0
0
0
1
Order By: Relevance
“…For heating the containers, a SNOL-type chamber furnace equipped with a Termodat-16E3 PID controller was used. All samples were packed in individual saturating containers, so that the sample itself did not come into direct contact with the saturating medium [5][6][7][8][9][10][11][12][13][14], but was located at a certain distance from its surface and were simultaneously loaded into a furnace pre-heated to 950 ° C and were soaked for 1.5 h after the samples attained the temperature of 950 °C. The samples were Grade 2 titanium plates with dimensions of 50 x 4 x 1 mm.…”
Section: Technique Of Experimentsmentioning
confidence: 99%
“…For heating the containers, a SNOL-type chamber furnace equipped with a Termodat-16E3 PID controller was used. All samples were packed in individual saturating containers, so that the sample itself did not come into direct contact with the saturating medium [5][6][7][8][9][10][11][12][13][14], but was located at a certain distance from its surface and were simultaneously loaded into a furnace pre-heated to 950 ° C and were soaked for 1.5 h after the samples attained the temperature of 950 °C. The samples were Grade 2 titanium plates with dimensions of 50 x 4 x 1 mm.…”
Section: Technique Of Experimentsmentioning
confidence: 99%
“…The samples for testing were obtained by the modes recommended [1][2][3][4][5][6][7][8][9][10][11]. Saturation was carried out in a saturating daub using a mixture that contained boron carbide, chromium compounds and titanium compounds.…”
Section: Introductionmentioning
confidence: 99%
“…Saturation was carried out in a saturating daub using a mixture that contained boron carbide, chromium compounds and titanium compounds. The exact chemical composition of the used saturating medium is given in [1,3,7]. Heating and holding of the samples were carried out in a chamber thermal furnace of the SNOL type, equipped with a PID controller.…”
Section: Introductionmentioning
confidence: 99%
“…Температура насыщения составила 1150 °С для сплава ВК8 и стали Р6М5 и 920 °С для стали У10; время насыщения для всех материалов было выбрано одинаковое -2,5 ч. Обработку образцов ВК8 и стали У10 осуществляли в камерной печи типа СНОЛ, осна-щенной ПИД-контроллером «Термодат 16Е-3». Обра-ботку образцов из стали Р6М5 осуществляли согласно рекомендациям работ [1,4,8]. После насыщения образ-цы из вольфрам-кобальтового спеченного материала ВК8 извлекали из печи, остужали на воздухе, после чего очищали от обмазки, промывали в мыльной воде.…”
unclassified