1995
DOI: 10.1016/0735-1097(95)91738-j
|View full text |Cite
|
Sign up to set email alerts
|

913-116 Quantitative Comparison of Planar and SPECT Normal Databases of Thallium-201, Sestamibi, Tetrofosmin and Furifosmin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
9
0
1

Year Published

1995
1995
2011
2011

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 0 publications
1
9
0
1
Order By: Relevance
“…Although disappearance of tracer from arterial blood is rapid, infusion system with prolonged administration time results in high myocardial blood-pool activity. 15 O-water is a freely diffusible tracer with a short physical half-life (2.1 min) requiring an on-site cyclotron. To effectively obtain myocardial images, 15 O-water (because of its short half-life) requires administration with rapid data acquisition.…”
Section: Current Status Of Pet Perfusion Tracersmentioning
confidence: 99%
See 2 more Smart Citations
“…Although disappearance of tracer from arterial blood is rapid, infusion system with prolonged administration time results in high myocardial blood-pool activity. 15 O-water is a freely diffusible tracer with a short physical half-life (2.1 min) requiring an on-site cyclotron. To effectively obtain myocardial images, 15 O-water (because of its short half-life) requires administration with rapid data acquisition.…”
Section: Current Status Of Pet Perfusion Tracersmentioning
confidence: 99%
“…15 O-water is a freely diffusible tracer with a short physical half-life (2.1 min) requiring an on-site cyclotron. To effectively obtain myocardial images, 15 O-water (because of its short half-life) requires administration with rapid data acquisition. Because water is distributed in both the vascular space and myocardium, visualization of myocardial activity with this tracer requires correction for activity in the vascular compartments, which makes the images difficult to interpret visually.…”
Section: Current Status Of Pet Perfusion Tracersmentioning
confidence: 99%
See 1 more Smart Citation
“…Myocardial perfusion has been traditionally evaluated with planar imaging or single photon emission computed tomography (SPECT), in conjunction with radiopharmaceuticals such as 201 Tl, [ 99m Tc]sestamibi or [ 99m Tc]tetrofosmin [1,2]. Currently, these types of myocardial perfusion imaging studies are part of normal patient workup and are performed on a routine basis.…”
Section: Introductionmentioning
confidence: 99%
“…Also in the domain of nuclear cardiology, few studies have been published on the comparison of normal SPET data obtained using different cameras or in different departments [8].…”
Section: Introductionmentioning
confidence: 99%