1984
DOI: 10.1093/jicru/os19.2.45
|View full text |Cite
|
Sign up to set email alerts
|

9. Radiative Stopping Power

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Unfortunately, this is not the case for a large number of clinical beam qualities and ionization chambers. Additionally, in the past these coefficients have been evaluated theoretically using Bragg-Gray cavity theory together with ICRU 37 data (Berger et al 1984). Such approach relies on different approximations, particularly with regard to the procedures to obtain chamber perturbation correction factors, which increase the uncertainty of the k Q,Q0 values in TRS 398.…”
Section: Trs 398 Formalism and The Beam Quality Correction Factormentioning
confidence: 99%
“…Unfortunately, this is not the case for a large number of clinical beam qualities and ionization chambers. Additionally, in the past these coefficients have been evaluated theoretically using Bragg-Gray cavity theory together with ICRU 37 data (Berger et al 1984). Such approach relies on different approximations, particularly with regard to the procedures to obtain chamber perturbation correction factors, which increase the uncertainty of the k Q,Q0 values in TRS 398.…”
Section: Trs 398 Formalism and The Beam Quality Correction Factormentioning
confidence: 99%
“…W air is the mean energy to create an ion pair in air at the beam qualities Q and 60 Co. For electron and photon radiation fields W air can be assumed to be independent from energy (Burns et al 2014). The aim of this work was to compare Monte Carlo calculated k Q values according to the recommendations of the new ICRU Report 90 (Seltzer et al 2014) and the ICRU Report 37 (Berger et al 1984). For this purpose the ratio of Monte Carlo calculated k Q values according to the ICRU Report 90 and 37 were determined.…”
Section: W D Detmentioning
confidence: 99%
“…In this respect, the ICRU Report 37 (Berger et al 1984) recommends values for the mean excitation energy I and the density of elements and compounds. Based on newer measurements, recommendations for the I values for graphite I g and water I w have been revised in the recent published ICRU Report 90 (Seltzer et al 2014), i.e.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation