2006 International Conference on Power System Technology 2006
DOI: 10.1109/icpst.2006.321423
|View full text |Cite
|
Sign up to set email alerts
|

800 KV HVDC for Transmission of Large Amount of Power Over Very Long Distances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…7, with the available capacities of 3000-4500 MW, 4500-6400 MW, and 6000-9000 MW respectively [2]. With the failure of one valve, the 12-pulse bridge has to be out of service until the fault valve is repaired and reinstalled.…”
Section: State Space For Converter Bridgementioning
confidence: 99%
See 2 more Smart Citations
“…7, with the available capacities of 3000-4500 MW, 4500-6400 MW, and 6000-9000 MW respectively [2]. With the failure of one valve, the 12-pulse bridge has to be out of service until the fault valve is repaired and reinstalled.…”
Section: State Space For Converter Bridgementioning
confidence: 99%
“…For short term evaluation, the instantaneous state probability P(t) is defined by (2). With given initial state P (t 0 ), P(t) and the corresponding unavailability U(t) are given by (3) and (4), where D is the subset of unavailable states.…”
Section: Instantaneous State Probabilitymentioning
confidence: 99%
See 1 more Smart Citation
“…-Energies produced at power stations are increased to kV levels with the step-up transformers to reduce Joule losses in long-distance transportations [1,2]. Consequently, many AC-DC transmission line projects up to 1200 kV have been constructed or are under way in many countries [3][4][5][6][7][8][9][10][11][12][13][14][15]. The application of high voltage in electrical power transmission is the most common, but electrical engineers also use this know-how in many other fields (e.g., [15][16][17][18][19][20][21]).…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, these transducers utilize oil-filled porcelain insulators to isolate the secondary parts from the primary parts, which make them not only very large and heavy, but also give them a high risk of explosion and fire. In particular, when a typical rated voltage of an HVDC project is up to 6800 kV (Asplund et al, 2006;Maruvada, 2008), galvanic isolation will be tighter and more significant. Therefore, the demand for novel direct current measurement devices for HVDC transmission system has arisen.…”
Section: Introductionmentioning
confidence: 99%