2008 International Conference on High Voltage Engineering and Application 2008
DOI: 10.1109/ichve.2008.4773882
|View full text |Cite
|
Sign up to set email alerts
|

800 kV Gas Insulated transmission Line Used in 207m vertical shaft

Abstract: The GIL covered voltage levels from 110 kV to 1000 kV. For Yellow River Laxiwa Hydropower Station, it's first 800 kV power plant in China. It's located at altitude of 2300 -2500 meters. In high voltage and high altitude areas, normal XLPE cable was limited to be used. This paper introduces particular issues of 800kV GIL in construction, design, manufacturing, erection and commissioning. And gives special recommendations for GIL applied in high fall vertical shaft and high altitude region.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Currently, the main methods for seismic analysis of electrical equipment are time course analysis and response spectrum analysis [12]. The response spectrum method can reflect the influence of seismic dynamic characteristics and structural dynamic characteristics on structural seismic response, and can determine the maximum response value of the structure [13]. The GIL structure studied in this paper is relatively complex, and the response spectrum method can be used to quantitatively grasp its dynamic characteristics and seismic response rules.…”
Section: Seismic Wave Selectionmentioning
confidence: 99%
“…Currently, the main methods for seismic analysis of electrical equipment are time course analysis and response spectrum analysis [12]. The response spectrum method can reflect the influence of seismic dynamic characteristics and structural dynamic characteristics on structural seismic response, and can determine the maximum response value of the structure [13]. The GIL structure studied in this paper is relatively complex, and the response spectrum method can be used to quantitatively grasp its dynamic characteristics and seismic response rules.…”
Section: Seismic Wave Selectionmentioning
confidence: 99%
“…Ceramic dielectrics are preferred for stage capacitors, due to their high voltage capability and relatively compact size. In some design variations, polyester film capacitors with line frequency excitation is used [8]. The capacitance value has direct influence in ripple and regulation of the multiplier.…”
Section: Stage Capacitorsmentioning