2012
DOI: 10.5405/jmbe.848
|View full text |Cite
|
Sign up to set email alerts
|

Untitled

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…We employed an analog passive circuit scheme to build the system, which minimized the size of the IPG prototype circuit and did not need a power supply. Unlike the previously published iteration [30], which used a NE555 chip whose pulse output width and frequency could not be adjusted, our single-channel IPG has a two-stage signal generator circuit to regulate the width and frequency of the pulse voltage output. The first stage uses an ICL8038, which regulates the frequency of the output signal.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…We employed an analog passive circuit scheme to build the system, which minimized the size of the IPG prototype circuit and did not need a power supply. Unlike the previously published iteration [30], which used a NE555 chip whose pulse output width and frequency could not be adjusted, our single-channel IPG has a two-stage signal generator circuit to regulate the width and frequency of the pulse voltage output. The first stage uses an ICL8038, which regulates the frequency of the output signal.…”
Section: Discussionmentioning
confidence: 99%
“…As seen in Figure 4a, the external part includes a signal generator, carrier oscillator, amplitude modulation (AM) circuit, and power amplifier circuit supplied by regulated direct-current (DC) power supplies. We developed the implant interface with the external part modified from a previously described setup [30]. The implanted part includes a microcoil, passive demodulated circuit, and surface electrodes (Figure 5a).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…and positron emission tomography are the most frequently used techniques for the diagnosis of gallbladder abnormalities [9][10][11]. Unfortunately, the positive predictive value of these strategies in the early detection of gallbladder carcinoma has been consistently <10% [12], including the utilization of the complex longitudinal algorithms for CA199 [13], sequential testing [14,15], and the addition of newer markers such as XPC [16].…”
mentioning
confidence: 99%