2020
DOI: 10.1016/j.jcin.2019.12.026
|View full text |Cite
|
Sign up to set email alerts
|

5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

9
85
2
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 139 publications
(98 citation statements)
references
References 31 publications
9
85
2
2
Order By: Relevance
“…In the randomized CHOICE study, which compared two types of valves, a five-year mortality rate of 53.4% in the balloon-expandable and 47.6% in the self-expanding valve group were observed, with no statistically significant differences. Both groups were comparable to each other and our group of patients in terms of age (81.9 vs. 79.6 vs. 81 years) and surgical perioperative risk (Logistic ES 21.5% vs. 22.1% vs. 15.1%, respectively)[10].…”
supporting
confidence: 74%
“…In the randomized CHOICE study, which compared two types of valves, a five-year mortality rate of 53.4% in the balloon-expandable and 47.6% in the self-expanding valve group were observed, with no statistically significant differences. Both groups were comparable to each other and our group of patients in terms of age (81.9 vs. 79.6 vs. 81 years) and surgical perioperative risk (Logistic ES 21.5% vs. 22.1% vs. 15.1%, respectively)[10].…”
supporting
confidence: 74%
“…They noted no difference in all-cause mortality or paravalvular leak. 63 However, the incidence of new pacemaker implantation was higher for the Nitinol self-expanding valves which could be due to the constant radial force exerted by the self-expanding valves leading to disruption of the conduction system. 63 This finding has been confirmed by a number of other studies including the CENTER-collaboration and PRAGMATIC Plus Initiative.…”
Section: Shape Memory Alloys In Transcatheter Valvesmentioning
confidence: 97%
“…63 However, the incidence of new pacemaker implantation was higher for the Nitinol self-expanding valves which could be due to the constant radial force exerted by the self-expanding valves leading to disruption of the conduction system. 63 This finding has been confirmed by a number of other studies including the CENTER-collaboration and PRAGMATIC Plus Initiative. 61,64,65 There is conflicting evidence whether there is a difference in incidence of stroke when comparing self-expanding and balloon-expanding valves.…”
Section: Shape Memory Alloys In Transcatheter Valvesmentioning
confidence: 97%
“…Die jetzt verfügbaren 5-Jahres-Ergebnisse bestätigen die insgesamt sehr hohe Mortalität des Studienkollektivs (ca. 50 % nach 5 Jahren) [2]. Hinsichtlich der klinischen Endpunkte gab es keine signifikanten Unterschiede zwischen beiden Klappenmodellen.…”
Section: Langzeitergebnisse Aus Randomisierten Studienunclassified
“…Die Hämodynamik stellte sich allerdings bei der supraanulären selbstexpandierenden Klappe etwas besser dar. Einschränkend muss angemerkt werden, dass es sich jeweils um frühe -nicht mehr erhältliche Klappenmodelle handelt [2].…”
Section: Langzeitergebnisse Aus Randomisierten Studienunclassified