2020
DOI: 10.35459/tbp.2019.000113
|View full text |Cite
|
Sign up to set email alerts
|

4f Koehler Transmitted Illumination Condenser for Teaching and Low-Cost Microscopic Imaging

Abstract: Transmitted light imaging is an important tool in biophysics for applications that include sample analysis, recording samples whose viability is compromised by high levels of illumination (e.g., live cell tracking), and finding regions of interest in a sample. Koehler transillumination is a powerful illumination method used in commercial microscopes; yet commercial Koehler condensers are expensive, are difficult to integrate into tabletop systems, and make learning the concepts of Koehler illumination difficul… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…The assembly and alignment protocols were described in a previous study. [ 37 ] Light intensity in front of the cuvette was measured after each adjustment of field diameter and/or aperture diameter using a power meter.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The assembly and alignment protocols were described in a previous study. [ 37 ] Light intensity in front of the cuvette was measured after each adjustment of field diameter and/or aperture diameter using a power meter.…”
Section: Methodsmentioning
confidence: 99%
“…[35,36] Here, microfilaments with varying diameter ranges were fabricated by adjusting the spatial coherence length using a standard Köhler illumination system consisting of a 405 nm light-emitting diode light source. [37] Specifically, this light-induced selforganization depends on spatial coherence of the light source and strength of the photoreactive material's RI nonlinearity. [26] The more spatially coherent the light beam (i.e., the longer the spatial coherence length l c of the light beam), the broader the diameter of the microfilaments.…”
Section: Hydrogel Microfilaments For Cell Guidance Are Highly Aligned...mentioning
confidence: 99%
“…This observation system has the same principle of a fluorescence microscope, and it can project patterns and has a long working distance. The illumination system has a Köhler illumination 44 , 45 lens arrangement, and the imaging system has a reduction projection lens configuration 46 . A water-soluble fluorescent dye (eosin Y) was added to the emulsion to enable the differentiation between UV-pattern-exposed and -unexposed areas based on the fluorescence color (Table S2 ).…”
Section: Resultsmentioning
confidence: 99%
“…More details about the implemented optical system can be found in ref. [80] As well as the original photopolymerization setup (Figure S1, Supporting Information), illumination occurs from the bottom to the top for employing the same fabrication procedure described above. Here, the photo-patterned Au-pNIPAM films were cured for 2 min and then thoroughly rinsed with Milli-Q water to get rid of the unreacted resin.…”
Section: Methodsmentioning
confidence: 99%