2013
DOI: 10.1016/j.prro.2013.01.096
|View full text |Cite
|
Sign up to set email alerts
|

4D PET/CT: Radiology Imaging to Radiation Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
1
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
0
1
0
Order By: Relevance
“…For each patient, 18 F-FDG was the administered radiotracer, and the RG PET scan was acquired during the same session as the 3D PET scan in the same position per protocol for radiation treatment planning. A radiologist-approved 4D PET/CT protocol was applied for image acquisition [37] . The 3D PET/CT protocol was adapted for our institution from the Netherlands Protocol [38] .…”
Section: Methodsmentioning
confidence: 99%
“…For each patient, 18 F-FDG was the administered radiotracer, and the RG PET scan was acquired during the same session as the 3D PET scan in the same position per protocol for radiation treatment planning. A radiologist-approved 4D PET/CT protocol was applied for image acquisition [37] . The 3D PET/CT protocol was adapted for our institution from the Netherlands Protocol [38] .…”
Section: Methodsmentioning
confidence: 99%
“…Limited clinical acceptance of EDG PET was primarily supported by the study of 130 patients comparing EDG PET embedded in or separated from a whole-body PET scan, in which challenges were reported including long acquisition and reconstruction times and requiring a multidisciplinary team with a thorough understanding and execution of the process, from patient prep through scan acquisition. 21 This can also be supported by the use of DDG PET over EDG PET to maintain a simple and "practical" implementation in the clinic. 22 Putting or wrapping a respiratory monitoring device on the patient and increasing radiation exposure to the technologist were part of the patient prep and both limited the application of EDG PET.…”
Section: Introductionmentioning
confidence: 99%
“…22 Putting or wrapping a respiratory monitoring device on the patient and increasing radiation exposure to the technologist were part of the patient prep and both limited the application of EDG PET. 21,23,24 We have designed a new DDG CT to match with DDG PET. 17,25 The new DDG CT was derived from a low-dose cine CT scan of about 1.35 mSv for a coverage of about 15.4 cm.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…4D CT can be performed with a cine CT or a low-pitch helical CT and has become a standard imaging procedure for RT [19] , [20] . 4D PET/CT, on the other hand, has not been widely utilized due to its requirement of both 4D PET and 4D CT, complexity in implementation, and limited studies to suggest its clinical utility [16] , [21] , [22] , [23] .…”
Section: Introductionmentioning
confidence: 99%