2003
DOI: 10.1016/s0009-2614(02)01652-4
|View full text |Cite
|
Sign up to set email alerts
|

410-nm diode laser cavity ring-down spectroscopy for trace detection of NO2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
42
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 57 publications
(44 citation statements)
references
References 29 publications
2
42
0
Order By: Relevance
“…During the last decade cavity ring-down spectroscopy (CRDS) and its related forms cavity enhanced absorption spectroscopy (CEAS) and cavity attenuated phase shift spectroscopy (CAPS) have become powerful techniques to detect atmospheric trace gases (Ball and Jones, 2003;Brown, 2003) and have also been applied to NO 2 detection. A pulsed laser system , continuous wave laser diodes (Mazurenka et al, 2003;Kasyutich et al, 2003;Wada and Orr-Ewing, 2005;Kasyutich et al, 2006;Courtillot et al, 2006), light emitting diodes (LEDs) (Kebabian et al, 2005;Langridge et al, 2006;Gherman et al, 2008) and a xenon short-arc lamp (Venables et al, 2006) have been used as light sources.…”
Section: Intercomparison Saphirmentioning
confidence: 99%
“…During the last decade cavity ring-down spectroscopy (CRDS) and its related forms cavity enhanced absorption spectroscopy (CEAS) and cavity attenuated phase shift spectroscopy (CAPS) have become powerful techniques to detect atmospheric trace gases (Ball and Jones, 2003;Brown, 2003) and have also been applied to NO 2 detection. A pulsed laser system , continuous wave laser diodes (Mazurenka et al, 2003;Kasyutich et al, 2003;Wada and Orr-Ewing, 2005;Kasyutich et al, 2006;Courtillot et al, 2006), light emitting diodes (LEDs) (Kebabian et al, 2005;Langridge et al, 2006;Gherman et al, 2008) and a xenon short-arc lamp (Venables et al, 2006) have been used as light sources.…”
Section: Intercomparison Saphirmentioning
confidence: 99%
“…NO 2 can be well detected with blue violet lasers (0.4-0.42 µm). Such approach was already demonstrated by several laboratories [10][11][12][13][14][15]. Mean value of the absorption cross--section in this region reaches about 6 × 10 −19 cm 2 .…”
Section: Introductionmentioning
confidence: 74%
“…10 Additionally, NO 2 presents larger absorption lines in the blue region, and it is likely that the sensitivity could be further increased using blue diode lasers in remote absorption measurements. 21,22 Unfortunately, presently available blue diode lasers typically operate on several modes and need to be assembled in external-cavity arrangements that reduce the available output power considerably.…”
Section: Discussionmentioning
confidence: 99%