2019
DOI: 10.1007/s13738-019-01823-y
|View full text |Cite
|
Sign up to set email alerts
|

4, 4′-Diamino-4″-methoxytriphenylamine as highly sensitive fluorimetric sensor for the determination of water in organic solvents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 30 publications
1
2
0
Order By: Relevance
“…Besides, the limit of detection (LOD) values of water in the different solvent were calculated by using equation detection limit=3S/k, where S is the standard deviation of the blank measurement and k is the slope between the fluorescence intensity versus V/V % of water. The LOD values obtained were in the range of 0.003–1.5 V/V% (Table S1, Figure S17) for different solvent pairs where water is one of the essential components among the solvent pair and it is comparable to the previous reports [47,48] . Along with that the selectivity of the HL1 probe towards water has been determined in a mixture of two solvent combinations through fluorescence spectroscopy.…”
Section: Resultssupporting
confidence: 64%
See 1 more Smart Citation
“…Besides, the limit of detection (LOD) values of water in the different solvent were calculated by using equation detection limit=3S/k, where S is the standard deviation of the blank measurement and k is the slope between the fluorescence intensity versus V/V % of water. The LOD values obtained were in the range of 0.003–1.5 V/V% (Table S1, Figure S17) for different solvent pairs where water is one of the essential components among the solvent pair and it is comparable to the previous reports [47,48] . Along with that the selectivity of the HL1 probe towards water has been determined in a mixture of two solvent combinations through fluorescence spectroscopy.…”
Section: Resultssupporting
confidence: 64%
“…The LOD values obtained were in the range of 0.003-1.5 V/V% (Table S1, Figure S17) for different solvent pairs where water is one of the essential components among the solvent pair and it is comparable to the previous reports. [47,48] Along with that the selectivity of the HL1 probe towards water has been determined in a mixture of two solvent combinations through fluorescence spectroscopy. The results indicated that the HL1 probe selectively senses water by turning off the emission over other solvents (Figure S18).…”
Section: Resultsmentioning
confidence: 99%
“…It is considered as a gold standard for water content measurements according to multiple publications. [13][14][15][16] ASTM International (ASTM) also published a standard test method for water in organic liquids by coulometric KF. 17 However, it is a destructive technique, requires a specic reagent, and takes considerable time for one measurement.…”
Section: Introductionmentioning