3D Transcranial Ultrasound Localization Microscopy in the Rat Brain With a Multiplexed Matrix Probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
65
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 55 publications
(67 citation statements)
references
References 62 publications
1
65
0
1
Order By: Relevance
“…The 1024 channel system could be replaced by a single 256 channels system combined with electronic multiplexors, as it was recently demonstrated on the rat brain. 22 This approach, however, requires longer acquisition times and more importantly induces a significant loss of the temporal resolution. In this last study, 22 the use of 4:1 multiplexors reduced the volume rate by ten times.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The 1024 channel system could be replaced by a single 256 channels system combined with electronic multiplexors, as it was recently demonstrated on the rat brain. 22 This approach, however, requires longer acquisition times and more importantly induces a significant loss of the temporal resolution. In this last study, 22 the use of 4:1 multiplexors reduced the volume rate by ten times.…”
Section: Discussionmentioning
confidence: 99%
“… 22 This approach, however, requires longer acquisition times and more importantly induces a significant loss of the temporal resolution. In this last study, 22 the use of 4:1 multiplexors reduced the volume rate by ten times. Such a strong imaging rate reduction affects the quality of velocity estimates in particular in large vessels.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…3DULM was extensively detailed in our previous paper 30 including all specifications on the volumetric ultrasound sequence, the transcranial brain imaging on rat, and the ULM post-processing. Briefly, volumes were acquired on an ultrafast research scanner Vantage 256 (Verasonics, Kirkland, USA) with a 32 × 32 ultrasonic matrix probe (central frequency 7.8 MHz, 300 µm pitch).…”
Section: Methodsmentioning
confidence: 99%
“…The elevation projection was solved with the emergence of volumetric imaging by combining thousands of transducers for 3DULM 26 29 . The system reaches a large field of view, an unbiased velocity estimation, and a quasi-isotropic resolution in-depth even though the intact skull bone 30 .…”
Section: Introductionmentioning
confidence: 99%