2012
DOI: 10.1016/j.icheatmasstransfer.2011.09.004
|View full text |Cite
|
Sign up to set email alerts
|

3D simulation of laminar flow and heat transfer in V-baffled square channel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
58
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 66 publications
(59 citation statements)
references
References 22 publications
1
58
0
Order By: Relevance
“…• To keep similarly flow structure and efficiency as the V-shaped baffle • To decrease the pressure loss in the heating system when comparing with the V-baffle • To reduce the low heat transfer regime; four edges of the duct, behind the baffle • To present a new design of the vortex generator, which easy forming and installing in the real system (the concept for installation is stated by Promvonge et al, 2012b) The influences of the blockage ratios (b/H, BR = 0.05-0.20) and flow directions (V-Downstream and VUpstream) are numerically examined with the Reynolds number founded on the channel-hydraulic diameter, Re = 3000-20,000. The pitch ratio of 1 and the flow attack angle of 30° are selected for the present study due to the best thermal efficiency was found at this point .…”
Section: Introductionmentioning
confidence: 99%
“…• To keep similarly flow structure and efficiency as the V-shaped baffle • To decrease the pressure loss in the heating system when comparing with the V-baffle • To reduce the low heat transfer regime; four edges of the duct, behind the baffle • To present a new design of the vortex generator, which easy forming and installing in the real system (the concept for installation is stated by Promvonge et al, 2012b) The influences of the blockage ratios (b/H, BR = 0.05-0.20) and flow directions (V-Downstream and VUpstream) are numerically examined with the Reynolds number founded on the channel-hydraulic diameter, Re = 3000-20,000. The pitch ratio of 1 and the flow attack angle of 30° are selected for the present study due to the best thermal efficiency was found at this point .…”
Section: Introductionmentioning
confidence: 99%
“…They reported that the fully developed periodic profiles are found around x/D = 7. Promvonge et al (2012) applied the periodic boundary for inlet and outlet of the square channel heat exchanger placed with Vbaffles. They found that the fully developed periodic profiles on flow and heat transfer are around x/D = 8 downstream of the entry.…”
Section: Introductionmentioning
confidence: 99%
“…Promvonge et al [8] presented a numerical investigation on laminar flow and heat transfer characteristics in a threedimensional isothermal wall square-channel fitted with inline 45 ∘ V-shaped baffles on two opposite walls. Apparently the longitudinal counter-rotating vortex flows created by the Vbaffle can induce impingement/attachment flows over the walls resulting in a greater increase in heat transfer over the test channel.…”
Section: Introductionmentioning
confidence: 99%
“…In [8,9], the heat transfer augmentation leads to the increase in enlarging pressure. Therefore, the improvement of vortex generators is to reduce the pressure loss that is done by study parameters of the vortex generators, especially, flow attack angle of the vortex generators.…”
Section: Introductionmentioning