3D Contrast Enhanced Ultrasound for Detecting Endoleak Following Endovascular Aneurysm Repair (EVAR)

Abstract: 3D CEUS may be more sensitive to endoleak following EVAR than either 2D CEUS or CTA.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

3
57
0
9

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 63 publications
(71 citation statements)
references
References 22 publications
3
57
0
9
Order By: Relevance
“…In the present case, the Doppler US and CEUS surveillance post-EVAR were sufficient to diagnose the presence of a leak at the level of the prostheses and to quantify the arterial flow inside the leak, as affirmed in similar recent literature reports [20][21][22][23]. Informations about the haemodynamic of the leak are of particular interest as a high flow leak requires immediate treatment.…”
Section: Discussionsupporting
confidence: 57%
See 1 more Smart Citation
“…In the present case, the Doppler US and CEUS surveillance post-EVAR were sufficient to diagnose the presence of a leak at the level of the prostheses and to quantify the arterial flow inside the leak, as affirmed in similar recent literature reports [20][21][22][23]. Informations about the haemodynamic of the leak are of particular interest as a high flow leak requires immediate treatment.…”
Section: Discussionsupporting
confidence: 57%
“…Actually standard echography is considered as insufficient for direct use but CEUS has reliability and specificity to be a correct alternative to CT angiography [21,22]. Only if we consider that CEUS avoids potential induced nephropathies caused by repeated ionizations, the alternative is suitable.…”
Section: Discussionmentioning
confidence: 99%
“…This imaging modality involves the use of magnetic field emitters to place and orientate a sonographic probe. In a pilot study of 23 patients, Abbas et al compared the abilities of three diagnostic methods (three‐dimensional CEUS, two‐dimensional CEUS, and CTA) to detect an endoleak. EL‐II were identified in 18 patients, and only three‐dimensional CEUS could identify their inflow and outflow vessels.…”
Section: Discussionmentioning
confidence: 99%
“…The use of Computed Tomography Angiography (CTA), which is currently recommended for the follow-up of patients undergoing EVAR, puts the patients at risk of receiving high doses of ionizing radiation and exposes them to the repetitive impact of nephrotoxic X-ray contrast [1, 2]. …”
mentioning
confidence: 99%
“…High-resolution contrast-enhanced ultrasound (CEUS) is one of the alternative methods used to detect and characterize endoleaks [1, 2]. The advent of CEUS imaging utilizing sulfur hexafluoride microbubbles as a contrast agent improved the resolution and sensitivity of microvessel visualization.…”