A multi-laboratory benchmark study of isothermal titration calorimetry (ITC) using Ca2+ and Mg2+ binding to EDTA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2
2

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 34 publications
1
8
0
Order By: Relevance
“…ITC is a conventional characterization method that uniquely measures binding reactions by detecting heat changes during the formation of complexes in various physicochemical processes. While ITC has been extensively reported in research involving metal ions and biomolecules [ 41 , 42 , 43 , 44 ], there are fewer reports concerning anions. The ITC data analysis software (v1.41) employs a non-linear regression, an iterative process where model variables are determined by making a series of approximations to the ITC titration curve.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…ITC is a conventional characterization method that uniquely measures binding reactions by detecting heat changes during the formation of complexes in various physicochemical processes. While ITC has been extensively reported in research involving metal ions and biomolecules [ 41 , 42 , 43 , 44 ], there are fewer reports concerning anions. The ITC data analysis software (v1.41) employs a non-linear regression, an iterative process where model variables are determined by making a series of approximations to the ITC titration curve.…”
Section: Resultsmentioning
confidence: 99%
“…ITC is a conventional characterization method that uniquely measures binding reactions by detecting heat changes during the formation of complexes in various physicochemical processes. While ITC has been extensively reported in research involving metal ions and biomolecules [41][42][43][44], there are fewer reports concerning anions. The ITC…”
Section: Reversibility and Reusability Of Probementioning
confidence: 99%
“…EDTA acted as a control as it is a strong chelator of Ca 2+ and Mg 2+ . 41 We performed a turbidimetric precipitation assay to qualitatively determine the amount of precipitation observed in the varied solutions. IP6 precipitated out of solution in the presence of low and high concentrations of CaCl2 and MgCl2 at pH's found in the small and large intestines.…”
Section: Characterization Of Ip6 Analog Binding To Divalent Cationsmentioning
confidence: 99%
“…EDTA acted as a control as it is a strong chelator of Ca 2+ and Mg 2+ . 41 We performed a turbidimetric precipitation assay to qualitatively determine the amount of precipitation observed in the varied solutions. IP6 precipitated out of solution in the presence of low and high concentrations of CaCl2 and MgCl2 at pH's found in the small and large intestines.…”