2021
DOI: 10.1016/j.placenta.2021.03.017
|View full text |Cite
|
Sign up to set email alerts
|

First-trimester utero-placental (vascular) development and embryonic and fetal growth: The Rotterdam periconception cohort

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 41 publications
0
6
0
Order By: Relevance
“…7A). Both PV and uPVV increase significantly throughout the first trimester (Reijnders et al, 2021). The PV and the uPVV increased at a higher rate than the amounts of uPVS characteristics, resulting in a significant decrease in the density of vascular branching in PV (uPVS:PV ratio) (data not shown) and uPVV (uPVS:uPVV ratio) between 7-9-11 weeks GA (Fig.…”
Section: Upvs Development and Density Of Vascular Branching In The Fi...mentioning
confidence: 81%
“…7A). Both PV and uPVV increase significantly throughout the first trimester (Reijnders et al, 2021). The PV and the uPVV increased at a higher rate than the amounts of uPVS characteristics, resulting in a significant decrease in the density of vascular branching in PV (uPVS:PV ratio) (data not shown) and uPVV (uPVS:uPVV ratio) between 7-9-11 weeks GA (Fig.…”
Section: Upvs Development and Density Of Vascular Branching In The Fi...mentioning
confidence: 81%
“…This technique has been extensively described by Reijnders and colleagues [ 4 ], and is a reliable reflection of the uPVV of the maternal side of the placental bed with intra-class correlation coefficients > 0.94 [ 4 ]. Standardized settings for the power Doppler ultrasound were used to obtain scans of the utero-placental vasculature (power Doppler gain ‘-8.0’, pulse repetition frequency ‘0.6 kHz’, wall motion filter ‘low 1’, quality ‘high’) [ 4 , 27 ]. Furthermore, the following default instrument settings were used throughout the examinations: frequency, low; dynamic, set 5; balance, 180; smooth, 4/5; ensemble, 12; line density, 8; power Doppler map, 5; artifact suppression, on; power Doppler line filter, 1; quality, high.…”
Section: Methodsmentioning
confidence: 99%
“…Associations between utero-placental vascular development and prenatal growth have been investigated by a variety of ultrasound markers, including placental volume (PV), vascularization and flow indices, and uterine artery Dopplers ( Collins et al , 2013 ; Reus et al , 2014 ; Velauthar et al , 2014 ; Alfirevic et al , 2017 ; Chen et al , 2022 ). Evidence suggests utero-placental vascular development and prenatal growth are associated with conception method and fetal sex ( Clifton, 2010 ; Broere-Brown et al , 2016 ; Rizzo et al , 2016 ; Cavoretto et al , 2020 ; Reijnders et al , 2021 ). Combining three-dimensional (3D) power Doppler (PD) ultrasound and virtual reality (VR), a recent study showed positive associations between utero-placental vascular volume (uPVV) development and embryonic growth, with fetal sex specific modifications ( Reijnders et al , 2021 ).…”
Section: Introductionmentioning
confidence: 99%