1999
DOI: 10.1002/(sici)1096-9888(199909)34:9<909::aid-jms849>3.0.co;2-a
|View full text |Cite
|
Sign up to set email alerts
|

337 nm Matrix-assisted laser desorption/ionization of single aerosol particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
29
0

Year Published

2000
2000
2008
2008

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(30 citation statements)
references
References 22 publications
(26 reference statements)
1
29
0
Order By: Relevance
“…Sampling standard particles composed of mixtures of matrix-assisted laser desorption ionization (MALDI) matrix and analyte provides a means to produce ions of a given m/z [3][4][5] and assess the instrument performance over a range of masses. The reflectron time-offlight (TOF) instrument was unable to detect ion signals from standard MALDI particles of angiotensin (MW ϭ 1297 Da) and ␣-cyclodextrin (MW ϭ 973 Da) but readily detected matrix ions.…”
Section: B Ioaerosol Mass Spectrometry (Bams) Has Recentlymentioning
confidence: 99%
See 1 more Smart Citation
“…Sampling standard particles composed of mixtures of matrix-assisted laser desorption ionization (MALDI) matrix and analyte provides a means to produce ions of a given m/z [3][4][5] and assess the instrument performance over a range of masses. The reflectron time-offlight (TOF) instrument was unable to detect ion signals from standard MALDI particles of angiotensin (MW ϭ 1297 Da) and ␣-cyclodextrin (MW ϭ 973 Da) but readily detected matrix ions.…”
Section: B Ioaerosol Mass Spectrometry (Bams) Has Recentlymentioning
confidence: 99%
“…Single particle MALDI experiments provide a suitable system to access the performance of the instrument [5][6][7]. Gramicidin S particles were generated from a 50/50 H 2 O/ethanol solution of 2,5-dihydroxybenzoic acid (DHB; 3 ϫ 10 Ϫ3 M) and gramicidin S at a 100:1 matrixto-analyte molar ratio.…”
Section: Particle Generation and Samplingmentioning
confidence: 99%
“…It has not been as well studied as bulk MALDI, but it does provide a unique opportunity for fundamental research into the MALDI process. The analysis of aerosol particles containing analyte and matrix was first reported in 1993 by Murray and coworkers [26], who would go on to publish numerous papers on the subject [27][28][29][30][31][32][33][34]. In 1996, however, Mansoori et al were the first to analyze such particles individually in a single particle TOFMS [35].…”
mentioning
confidence: 99%
“…Baseline resolution was observed and a resolution of 5000 (measured at FWHM) was calculated for the parent ions. This observed resolution is approximately an order of magnitude greater than that reported for timeof-flight-based aerosol MALDI [12,16,17,24]. In those instruments, aerosol beam width and methods of sample preparation have been suggested as limiting resolutions [13].…”
Section: Resultsmentioning
confidence: 99%
“…With their technique, they generated mass spectra of individual bacterial spores [12,13]. Other groups have also demonstrated MALDI on a single-particle level by either on-line coating of the particles [14,15] or premixing the matrix and analyte [16,17].…”
Section: Introductionmentioning
confidence: 99%