2021
DOI: 10.1021/acsomega.0c04929
|View full text |Cite
|
Sign up to set email alerts
|

Machine Learning-Driven and Smartphone-Based Fluorescence Detection for CRISPR Diagnostic of SARS-CoV-2

Abstract: Rapid, accurate, and low-cost detection of SARS-CoV-2 is crucial to contain the transmission of COVID-19. Here, we present a cost-effective smartphone-based device coupled with machine learning-driven software that evaluates the fluorescence signals of the CRISPR diagnostic of SARS-CoV-2. The device consists of a three-dimensional (3D)-printed housing and low-cost optic components that allow excitation of fluorescent reporters and selective transmission of the fluorescence emission to a smartphone. Custom soft… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
40
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 49 publications
(41 citation statements)
references
References 24 publications
1
40
0
Order By: Relevance
“…Images captured with the phone camera are then sent to the cloud where a machine learning algorithm will be used for result interpretation. The LoD of this RT-RPA-DETECTR assay (6.25 copies/µL) was comparable to the RT-LAMP-DETECTR assay (10 copies/µL) developed by Broughtonet al [14], but higher than that of rRT-PCR (1-3.2 copies/µL) [14,36,80]. The PPA and NPA of the RT-LAMP-DETECTR assay relative to rRT-PCR (n = 82; PPA = 95%; NPA = 100%) [14] were also better than the RT-RPA-DETECTR assay (n = 115; PPA = 87%; NPA = 92%) [36].…”
Section: Cas12-based Crispr-dx 41 Two-pot Assayssupporting
confidence: 60%
See 4 more Smart Citations
“…Images captured with the phone camera are then sent to the cloud where a machine learning algorithm will be used for result interpretation. The LoD of this RT-RPA-DETECTR assay (6.25 copies/µL) was comparable to the RT-LAMP-DETECTR assay (10 copies/µL) developed by Broughtonet al [14], but higher than that of rRT-PCR (1-3.2 copies/µL) [14,36,80]. The PPA and NPA of the RT-LAMP-DETECTR assay relative to rRT-PCR (n = 82; PPA = 95%; NPA = 100%) [14] were also better than the RT-RPA-DETECTR assay (n = 115; PPA = 87%; NPA = 92%) [36].…”
Section: Cas12-based Crispr-dx 41 Two-pot Assayssupporting
confidence: 60%
“…The reported LoD for these one-pot assays ranged from 2.5 copies/µL to 45 copies/µL and achieved 97%-100% concordance with rRT-PCR results when tested with clinical specimens (n = 14-100) [54][55][56]. Like Samacoits et al [36], Chen et al [53] also capitalized on 3D printing technology to fabricate a portable instrument for fluorescence imaging with a smartphone camera, but result interpretation was based on visual inspection instead of a cloud-based analysis and the LoD attained was 20 copies/reaction [53].…”
Section: One-pot Assaysmentioning
confidence: 55%
See 3 more Smart Citations