2021
DOI: 10.1093/clinchem/hvaa336
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of High-Throughput SARS-CoV-2 Serological Assays in a Longitudinal Cohort of Patients with Mild COVID-19: Clinical Sensitivity, Specificity, and Association with Virus Neutralization Test

Abstract: Background The association between SARS-CoV-2 commercial serological assays and virus neutralization test (VNT) has been poorly explored in mild patients with COVID-19. Methods 439 serum specimens were longitudinally collected from 76 healthcare workers with RT-PCR-confirmed COVID-19. The clinical sensitivity (determined weekly) of nine commercial serological assays were evaluated. Clinical specificity was assessed using 69 p… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
66
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 74 publications
(68 citation statements)
references
References 32 publications
1
66
1
Order By: Relevance
“…Among those positive, in the total Ig ELISA, around 76% were positive for IgG. We ascribe this discrepancy from the fact that the total Ig sandwich ELISA format provided by the Wantai system seems to be more sensitive than the direct IgG ELISA format as has been described previously 26 .…”
Section: Discussionmentioning
confidence: 79%
“…Among those positive, in the total Ig ELISA, around 76% were positive for IgG. We ascribe this discrepancy from the fact that the total Ig sandwich ELISA format provided by the Wantai system seems to be more sensitive than the direct IgG ELISA format as has been described previously 26 .…”
Section: Discussionmentioning
confidence: 79%
“…However, the ABBOTT assay appeared to show lower performance, especially after 120 days. Other groups have already observed this phenomenon in an earlier post-PCR period [8,9]. At the end of the summer of 2020, ABBOTT defined a doubtful zone for the interpretation of its results, probably showing poor adjustment of their positivity threshold.…”
Section: Discussionmentioning
confidence: 91%
“…In addition, it is time-consuming (5-7 days) and non-standardized [15]. To overcome these drawbacks, several investigators have developed a number of immunoassays, such as enzyme-linked (ELISA) and chemiluminescent immunoassays (CLIA), as surrogate of PRNT [16]. Although such tests showed broad degrees of variability pertaining to the sensitivity and specificity when compared with PRNT, their diagnostic accuracy, which combines sensitivity and specificity and is represented by the area under the curve (AUC) in the non-parametric receiver operating characteristic (ROC) curve method, is often suboptimal [17][18][19].…”
Section: The Convalescent Plasmamentioning
confidence: 99%