2021
DOI: 10.1016/j.ophtha.2020.07.009
|View full text |Cite
|
Sign up to set email alerts
|

Changes in Intraocular Pressure and Angle Structure after Dilation in Primary Angle-Closure Suspects with Visually Significant Cataract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…It has been reported that angle synechia might interfere with results measured by AS-OCT. 27 , 28 Therefore, the generalization of the results to patients with PACG warrants further study. 29 Finally, only Chinese patients were included in the study, and the studies in other ethnic populations are needed to confirm or refute the findings. 4 , 7 …”
Section: Discussionmentioning
confidence: 99%
“…It has been reported that angle synechia might interfere with results measured by AS-OCT. 27 , 28 Therefore, the generalization of the results to patients with PACG warrants further study. 29 Finally, only Chinese patients were included in the study, and the studies in other ethnic populations are needed to confirm or refute the findings. 4 , 7 …”
Section: Discussionmentioning
confidence: 99%
“…Anterior segment SS-OCT images were obtained before and after dilation (SS-1000, CASIA; Tomey, Japan). Four cross-sectional images corresponding to 8 axes of the anterior chamber were assessed, as described previously 11. For each image, the scleral spur and iris recess were both automatically marked by the SS-OCT system and manually corrected to complete anterior chamber measurements by a single masked examiner (M.Z.).…”
Section: Methodsmentioning
confidence: 99%
“…Four cross-sectional images corresponding to 8 axes of the anterior chamber were assessed, as described previously. 11 For each image, the scleral spur and iris recess were both automatically marked by the SS-OCT system and manually corrected to complete anterior chamber measurements by a single masked examiner (M.Z.). Images were analyzed using the manufacturer-provided software and the following parameters were collected: anterior chamber dimension parameters [anterior chamber depth (ACD), anterior chamber width (ACW), lens vault (LV)], angle parameters [angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular-iris angle (TIA)], and volume parameters [cornea volume (CV), anterior chamber volume (ACV), iris volume (IV)].…”
Section: Ss-oct Measurementsmentioning
confidence: 99%
See 2 more Smart Citations