Abstract: Quantitative ultrasound is used to characterize and stimulate osseointegration processes at the bone-implant interface (BII). However, the interaction between an ultrasonic wave and the implant remains poorly understood. This study aims at investigating the sensitivity of the ultrasonic response to the microscopic and macroscopic properties of the BII and to osseointegration processes. The reflection coefficient R of the BII was modeled for different frequencies using a two-dimensional finite element model. Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
47
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(50 citation statements)
references
References 72 publications
(62 reference statements)
3
47
0
Order By: Relevance
“…Figure 4a shows that for implants with laser-modified surfaces, ro reaches a local maximum for a value of W comprised between 30 and 60 μm depending on the surface roughness. This result may be explained by constructive interferences of the echoes of the soft tissue -bone interface and of the implant -soft tissue interface, as already described in (Heriveaux et al, 2018). When the value of W is sufficiently high so that these interferences disappear, ro finally decreases to reach a final value of around 0.88.…”
Section: B Influence Of the Roughnessmentioning
confidence: 61%
See 3 more Smart Citations
“…Figure 4a shows that for implants with laser-modified surfaces, ro reaches a local maximum for a value of W comprised between 30 and 60 μm depending on the surface roughness. This result may be explained by constructive interferences of the echoes of the soft tissue -bone interface and of the implant -soft tissue interface, as already described in (Heriveaux et al, 2018). When the value of W is sufficiently high so that these interferences disappear, ro finally decreases to reach a final value of around 0.88.…”
Section: B Influence Of the Roughnessmentioning
confidence: 61%
“…The governing equations have been described in details in (Heriveaux et al, 2018) and the reader is referred to this publication for further details. Briefly, the classical equations of elastodynamic wave propagation in isotropic solids were considered.…”
Section: A Description Of the Numerical Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Another method consists of using quantitative ultrasound (QUS) (De Almeida et al 2007) to investigate the properties of the bone-implant interface. The principle of the measurement relies on the dependence of ultrasonic propagation within the implant on the boundary conditions prescribed by the biomechanical properties of the boneimplant interface (Mathieu et al 2011b) (Vayron et al 2013) (Vayron et al 2018b) (Vayron et al 2014a) (Vayron et al 2014b) (Vayron et al 2018a) (Mathieu et al 2011a) (Vayron et al 2015(Vayron et al , 2016Hériveaux et al 2018).…”
Section: Introductionmentioning
confidence: 99%