2018
DOI: 10.1097/hp.0000000000000888
|View full text |Cite
|
Sign up to set email alerts
|

Indoor and Outdoor Radon Concentration Levels in Lebanon

Abstract: Lebanon's lung cancer rates, among the highest in the Arab region, contribute to the burden of noncommunicable diseases. A number of studies have shown that lung cancer risk increases when smokers vs. nonsmokers exposed to elevated radon levels are compared. This research employs indoor and outdoor space and time concentration surveys across Lebanon, where the smoking rate among the population is among the highest in the world. The distributional properties of measured radon concentration were shown to be logn… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…Among passive detectors, solid state nuclear track detectors, polyallyl diglycol carbonate (PADC)—CR-39 were used in 40.7% of analysed surveys [ 45 , 46 , 77 , 82 , 83 , 89 , 92 , 93 , 94 , 95 , 96 ], polycarbonate foil of Makrofol in 7.4% [ 78 , 85 ], one survey (3.7%) with electrostatic integrating monitor based on LR115 [ 79 ]. One survey (3.7%) was performed by electret ion chamber (EPERM ® ) [ 81 ]. Active devices were used in 44.4% of the surveys, out of which: Two (7.4%) ionization chambers (AlphaGUARD) [ 74 , 97 ], four (14.8%) EEC Rn devices [ 75 , 98 , 99 , 100 ], five (18.5%) scintillators [ 66 , 87 , 91 , 101 , 102 ] and one (3.7%) Passivated Implanted Planar Silicon (PIPS) detector for alpha spectrometry [ 73 ].…”
Section: Measurement Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Among passive detectors, solid state nuclear track detectors, polyallyl diglycol carbonate (PADC)—CR-39 were used in 40.7% of analysed surveys [ 45 , 46 , 77 , 82 , 83 , 89 , 92 , 93 , 94 , 95 , 96 ], polycarbonate foil of Makrofol in 7.4% [ 78 , 85 ], one survey (3.7%) with electrostatic integrating monitor based on LR115 [ 79 ]. One survey (3.7%) was performed by electret ion chamber (EPERM ® ) [ 81 ]. Active devices were used in 44.4% of the surveys, out of which: Two (7.4%) ionization chambers (AlphaGUARD) [ 74 , 97 ], four (14.8%) EEC Rn devices [ 75 , 98 , 99 , 100 ], five (18.5%) scintillators [ 66 , 87 , 91 , 101 , 102 ] and one (3.7%) Passivated Implanted Planar Silicon (PIPS) detector for alpha spectrometry [ 73 ].…”
Section: Measurement Methodsmentioning
confidence: 99%
“…It is low cost and convenient for long-term measurements. However, results need corrections for background radiation and the surface should be free of dust, which could be a problem for outdoor measurements [ 81 ].…”
Section: Measurement Methodsmentioning
confidence: 99%
See 3 more Smart Citations