2016
DOI: 10.5334/jbr-btr.918
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Axial Traction during Direct MR-Arthrography of the Wrist in Sports Injuries

Abstract: Purpose:To evaluate the degree of joint distraction during direct MR arthrography with axial traction in sports injuries. To confirm the effect of axial traction on the quality of wrist opacification.Patients and methods:Seventeen patients (11 male, 6 female) underwent wrist MR arthrography without (mean: 39 years (SD 11.6))., and 20 patients (16 male, 4 female) with axial traction (mean: 28 years (SD 7.1)). Subgroups were defined according to pathology: degenerative, ligamentous, traumatic, normal (ie patient… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 17 publications
(29 reference statements)
0
1
0
Order By: Relevance
“…New-generation 3D turbo spin-echo (TSE) variants, such as 3D controlled aliasing in parallel imaging (CAIPIRINHA) SPACE TSE and 3D compressed sensing SPACE TSE, permit fourfold and sixfold acceleration for faster acquisition times for standard T1-, proton-density, intermediate-, and T2-weighting, optimized contrast resolution, and less blurring. 7,[23][24][25][26] The orientation of the in-plane phase encoding and partition phase encoding directions directly relates to the incidence of wraparound artifacts, whereas the voxel size is the major determinant for the overall SNR and overall image quality. 27 Negotiations and trade-offs between spatial resolution, acquisition time, and image contrast should be carefully chosen according to the clinical indications and the size and morphology of the structures that need to be assessed.…”
Section: D Mri Protocols and Pulse Sequencesmentioning
confidence: 99%
“…New-generation 3D turbo spin-echo (TSE) variants, such as 3D controlled aliasing in parallel imaging (CAIPIRINHA) SPACE TSE and 3D compressed sensing SPACE TSE, permit fourfold and sixfold acceleration for faster acquisition times for standard T1-, proton-density, intermediate-, and T2-weighting, optimized contrast resolution, and less blurring. 7,[23][24][25][26] The orientation of the in-plane phase encoding and partition phase encoding directions directly relates to the incidence of wraparound artifacts, whereas the voxel size is the major determinant for the overall SNR and overall image quality. 27 Negotiations and trade-offs between spatial resolution, acquisition time, and image contrast should be carefully chosen according to the clinical indications and the size and morphology of the structures that need to be assessed.…”
Section: D Mri Protocols and Pulse Sequencesmentioning
confidence: 99%