2018
DOI: 10.1016/j.jcv.2018.07.003
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic accuracy of digital RNA quantification versus real-time PCR for the detection of respiratory syncytial virus in nasopharyngeal aspirates from children with acute respiratory infection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 17 publications
1
5
0
Order By: Relevance
“…Due to financial limitations, only the pathogens reliably detected in both stages were used in subsequent experiments. Nonetheless, we have confirmed the detection of RSV-A/RSV-B, as shown here by nCounter, using RT-PCR ( Bouzas et al, 2018 ), and of H. influenzae, M. catarrhalis, S. aureus , and S. pneumoniae by 16S next-generation sequencing ( Andrade et al, 2016 ).…”
Section: Methodssupporting
confidence: 79%
See 1 more Smart Citation
“…Due to financial limitations, only the pathogens reliably detected in both stages were used in subsequent experiments. Nonetheless, we have confirmed the detection of RSV-A/RSV-B, as shown here by nCounter, using RT-PCR ( Bouzas et al, 2018 ), and of H. influenzae, M. catarrhalis, S. aureus , and S. pneumoniae by 16S next-generation sequencing ( Andrade et al, 2016 ).…”
Section: Methodssupporting
confidence: 79%
“…As described before in Fukutani et al (2015) and Bouzas et al (2018) , the nCounter probe set used in this study was extensively tested and optimized for semihigh throughput analysis. First, sensitivity, linearity, and absence of cross-reaction among the respiratory bacterial and viral targets were tested with a panel of positive controls obtained from the collection of the Laboratory of Clinical Virology (KU Leuven).…”
Section: Methodsmentioning
confidence: 99%
“…Standards and negative controls were included and tested with each PCR assay. One-step RT-PCR (Qiagen QuantiTect) targeting the conserved region of the F gene was performed using described primers and probes [17,18]. RSV quantification is reported as log 10 copies/mL.…”
Section: Rsv Loadsmentioning
confidence: 99%
“…Neena Kanwar et al compared the diagnostic accuracy of the two DIA tests with the real-time RT-PCR assay results as a reference, showing a sensitivity of 71.15% for BD VeritorTM System and 80.77% for Quidel ® Sofia ® RSV FIA system, and the specificity of 100% for both systems (15). The sensitivity and specificity of the nCounter (NanoString Technologies), which is a multiplex digital method of RNA quantification, in comparison to real-time RT-PCR were found to be 74.3% and 98.4% for RSV-A, 77.6% and 97.8% for RSV-B, respectively (16). Compared with the results of those studies, the colloidal-gold-Genesis showed higher sensitivity and lower specificity with a higher Youden index.…”
Section: Discussionmentioning
confidence: 99%