2018
DOI: 10.1016/j.aca.2017.12.035
|View full text |Cite
|
Sign up to set email alerts
|

A fully automated analytical platform integrating water sampling-miniscale-liquid-liquid extraction-full evaporation dynamic headspace concentration-gas chromatography-mass spectrometry for the analysis of ultraviolet filters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 41 publications
0
8
0
Order By: Relevance
“…Liew reported a fully automated sampling-sample preparationanalysis platform using a modified vial, peristaltic pump, mini-scale liquid−liquid extraction, evaporation, and GC−MS to measure six UV filters. 200 LODs ranged from 0.6 to 9.7 ng/ L, recoveries ranged from 62 to 80.7%, and good linearity was observed for benzhydrol, 2-ethylhexyl salicylate, homosalate, 2hydroxy-methoxybenzophenone, 3-(4′-methylbenzylidene)camphor, and benzophenone. This new method was subsequently demonstrated on swimming pool water, where recoveries ranged from 85.4 to 118.2%, and it was recommended for onsite water analysis.…”
Section: Analytical Chemistrymentioning
confidence: 97%
See 1 more Smart Citation
“…Liew reported a fully automated sampling-sample preparationanalysis platform using a modified vial, peristaltic pump, mini-scale liquid−liquid extraction, evaporation, and GC−MS to measure six UV filters. 200 LODs ranged from 0.6 to 9.7 ng/ L, recoveries ranged from 62 to 80.7%, and good linearity was observed for benzhydrol, 2-ethylhexyl salicylate, homosalate, 2hydroxy-methoxybenzophenone, 3-(4′-methylbenzylidene)camphor, and benzophenone. This new method was subsequently demonstrated on swimming pool water, where recoveries ranged from 85.4 to 118.2%, and it was recommended for onsite water analysis.…”
Section: Analytical Chemistrymentioning
confidence: 97%
“…Finally, there were some new methods reported for the measurement of UV filters in environmental waters. Liew reported a fully automated sampling-sample preparation-analysis platform using a modified vial, peristaltic pump, mini-scale liquid–liquid extraction, evaporation, and GC–MS to measure six UV filters . LODs ranged from 0.6 to 9.7 ng/L, recoveries ranged from 62 to 80.7%, and good linearity was observed for benzhydrol, 2-ethylhexyl salicylate, homosalate, 2-hydroxy-methoxybenzophenone, 3-(4′-methylbenzylidene)­camphor, and benzophenone.…”
Section: Sunscreens/uv Filtersmentioning
confidence: 99%
“…A mini scale LLE method was developed by Lee's group and used for water quality monitoring by coupling with a headspace concentration and gas chromatography/mass spectrometry (GC/MS). 99 This method allowed 15 mL sample prepared in 80 min. Although the time saving effect is limited when compared with normal LLE, it is still a theoretically feasible way to cut down the duration of sample preparation.…”
Section: ■ Size Reduction Accelerationmentioning
confidence: 99%
“…A mini scale LLE method was developed by Lee’s group and used for water quality monitoring by coupling with a headspace concentration and gas chromatography/mass spectrometry (GC/MS) . This method allowed 15 mL sample prepared in 80 min.…”
Section: Size Reduction Accelerationmentioning
confidence: 99%
“…9 Reviewing the reported toxicity studies of BZP and BZH revealed higher and wider toxic effects for BZP. [10][11][12][13] Cinnarizine (CIN), 1-(diphenylmethyl)-4-(3-phenyl-2propenyl)piperazine (Fig. 1d) is a piperazine derivative with antihistaminic and calcium channel blocking activities.…”
Section: Introductionmentioning
confidence: 99%