2007
DOI: 10.1016/j.finel.2007.05.005
|View full text |Cite
|
Sign up to set email alerts
|

3-D pushover analysis of a collapsed reinforced concrete chimney

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 4 publications
0
16
0
1
Order By: Relevance
“…However, studying the longitudinal and transverse flexure separately is conceptually wrong if material nonlinearities are involved, because the damage exerted to the tower due to its longitudinal flexure unavoidably affects the transverse response and vice versa. In order to overcome this drawback, and to consider the nonlinear modal interaction, the Coupled Nonlinear Static Pushover analysis (CNSP) is proposed here, rooted in EMPA (presented above) and in the proposal of Huang and Gould [19].…”
Section: Coupled Nonlinear Static Pushover Analysis: Cnspmentioning
confidence: 99%
See 3 more Smart Citations
“…However, studying the longitudinal and transverse flexure separately is conceptually wrong if material nonlinearities are involved, because the damage exerted to the tower due to its longitudinal flexure unavoidably affects the transverse response and vice versa. In order to overcome this drawback, and to consider the nonlinear modal interaction, the Coupled Nonlinear Static Pushover analysis (CNSP) is proposed here, rooted in EMPA (presented above) and in the proposal of Huang and Gould [19].…”
Section: Coupled Nonlinear Static Pushover Analysis: Cnspmentioning
confidence: 99%
“…These components are multiplied by the factor Λ, which takes into account the difference in the spectral accelerations associated with each governing mode [19]:…”
Section: Coupled Nonlinear Static Pushover Analysis: Cnspmentioning
confidence: 99%
See 2 more Smart Citations
“…Bu ise ana yapının özellikleri belirli olduğuna göre, AKS için optimum kütle, rijitlik ve sönüm değerlerinin belirlenmesi ile sağlanacaktır. Yapısal ve dinamik davranışları betonarme yüksek minarelere benzeyen betonarme yüksek bacalar için sönüm oranı oldukça düşüktür ve tipik olarak %2~5 aralığında değişir [20]. Başka bir örnek verilmek istenirse, yüksekliği 43 m olan betonarme bir su deposu üzerinde yapılan deneysel bir çalışmada sönüm oranı %2,65 olarak belirlenmiştir [21].…”
Section: Sönümlü Yapı Ve Sönümlü Aks (Damped Structure and Damped Tmd)unclassified