2013
DOI: 10.1016/j.ultrasmedbio.2012.10.010
|View full text |Cite
|
Sign up to set email alerts
|

3-D High-Frequency Ultrasound Improves the Estimation of Surface Properties in Degenerated Cartilage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(18 citation statements)
references
References 32 publications
0
18
0
Order By: Relevance
“…However, the reference reflector may not be identical in different studies. For example, in some previous studies the reference signal may be collected from PBS-air interface [5], sodium chloride-silicon rubber interface [8], PBS-PMMA interface [20] or physiologic saline-steel interface [17]. Also, assumptions are usually made that the acoustic characteristics of the reference material are known and fixed, but more or less, the real acoustic characteristics of reference material deviate from what has been assumed.…”
Section: Resultsmentioning
confidence: 99%
“…However, the reference reflector may not be identical in different studies. For example, in some previous studies the reference signal may be collected from PBS-air interface [5], sodium chloride-silicon rubber interface [8], PBS-PMMA interface [20] or physiologic saline-steel interface [17]. Also, assumptions are usually made that the acoustic characteristics of the reference material are known and fixed, but more or less, the real acoustic characteristics of reference material deviate from what has been assumed.…”
Section: Resultsmentioning
confidence: 99%
“…This work was based on the same set of measurements used in a previous study and reported in detail therein [4]. One to four punch biopsies (diameter: 8 mm) of degenerated cartilage were obtained from the femoral condyles of 19 patients, yielding 38 samples with variable degrees of degeneration.…”
Section: A Samplesmentioning
confidence: 99%
“…Cartilage samples were immersed at 25°C in PBS and measured in C-scan mode (scan increment: 20 μm in x and y direction) using the custom scanning acoustic microscope SAM200Ex [4,6]. The SAM is controlled by custom software (SAMEx, Q-BAM, Halle, Germany) and consists of a 3-axis high precision scanning stage, a 200 MHz pulser/receiver (Panametrics 5900PR, Waltham, USA) and a 500 MSs-1 A/Dcard (Gage CS8500, Gage Applied Technologies Inc., Lachine, Canada).…”
Section: Ultrasound Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, we have shown that 3D-UBM not only enables improved estimation of surface properties 5 , but also gives access to US backscatter parameters of the cartilage matrix 6 , whose analyses have been only sparsely carried out until now. Statistically significant differences of individual surface and backscatter parameters were found with respect to early structural and cellular degenerations, as assessed by the histologically derived Mankin subset score.…”
Section: Introductionmentioning
confidence: 99%