2010
DOI: 10.1016/j.radmeas.2009.11.012
|View full text |Cite
|
Sign up to set email alerts
|

2D-OSL-dosimetry with beryllium oxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
2

Year Published

2011
2011
2024
2024

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 32 publications
(7 citation statements)
references
References 9 publications
(15 reference statements)
0
5
0
2
Order By: Relevance
“…In 2010, Jahn et al presented a 2D dosimetric system for reading a BeO OSL area detector (ceramic plates commercialized as Thermalox 995 TM by Materion Ceramics, Inc.). They used a point-to-point reader of the BeO area, whose main limitations were spatial resolution (impaired by the scattering of stimulation light in the detector material) and long reading time of each detector (Jahn et al 2010). Subsequently, this system was improved using a fiber coupled to the LED for stimulation and with the possibility of using multiple fibers for simultaneous stimulation of eight detector points (Jahn et al 2011).…”
Section: D Dosimetry Using Beryllium Oxide Ceramic Platementioning
confidence: 99%
“…In 2010, Jahn et al presented a 2D dosimetric system for reading a BeO OSL area detector (ceramic plates commercialized as Thermalox 995 TM by Materion Ceramics, Inc.). They used a point-to-point reader of the BeO area, whose main limitations were spatial resolution (impaired by the scattering of stimulation light in the detector material) and long reading time of each detector (Jahn et al 2010). Subsequently, this system was improved using a fiber coupled to the LED for stimulation and with the possibility of using multiple fibers for simultaneous stimulation of eight detector points (Jahn et al 2011).…”
Section: D Dosimetry Using Beryllium Oxide Ceramic Platementioning
confidence: 99%
“…Jahn et al 76 mediram imagens de dose 2D com o sistema BeOmax realizando estimulação OSL com luz focada em um ponto de 0,5 mm de diâmetro e adquirindo varreduras linha a linha. Recentemente, o potencial dos filmes de Al 2 O 3 :C ou Al 2 O 3 :C,Mg como OSLD para dosimetria 2D foi demonstrado por Ahmed et al 77 , que desenvolveram e testaram um sistema de varredura a laser 78 .…”
Section: Dosimetria Bidimensional (2d)unclassified
“…BeO is a well-known luminescent material with excellent tissue equivalence for photon and electron radiation [7][8][9][10]. The material has been used as an OSL detector in personal and scientific dosimetry systems for more than a decade [11][12][13][14][15][16][17][18]. The RL of BeO has been shown to be linear to the applied dose rate in photon fields [19].…”
Section: Jinst 13 P10015mentioning
confidence: 99%