2017
DOI: 10.1016/j.bios.2017.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Enzyme-less electrochemical displacement heterogeneous immunosensor for diclofenac detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…This is most likely a consequence of high matrix interfering effects of saline matrixes in the detection scheme that can be overcome by using the flow-based kinetic-controlled detection system herein reported. It should also be stressed the fact that the reproducibility of manual immunoassays/biosensors might amount to RSD values as high as 23–100%. ,,, Most importantly, the minimum spiked concentration level of DCF in all of the previous works spanned from 15 to 1000 ng/L, ,− , again indicating that none of the immunoassays is suitable for detection of DCF at the environmental quality standard level set in seawater, that is, 10 ng/L.…”
Section: Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…This is most likely a consequence of high matrix interfering effects of saline matrixes in the detection scheme that can be overcome by using the flow-based kinetic-controlled detection system herein reported. It should also be stressed the fact that the reproducibility of manual immunoassays/biosensors might amount to RSD values as high as 23–100%. ,,, Most importantly, the minimum spiked concentration level of DCF in all of the previous works spanned from 15 to 1000 ng/L, ,− , again indicating that none of the immunoassays is suitable for detection of DCF at the environmental quality standard level set in seawater, that is, 10 ng/L.…”
Section: Resultsmentioning
confidence: 98%
“…It should also be stressed the fact that the reproducibility of manual immunoassays/ biosensors might amount to RSD values as high as 23− 100%. 6,49,50,54 Most importantly, the minimum spiked concentration level of DCF in all of the previous works spanned from 15 to 1000 ng/L, 6,49−52,54−56 again indicating that none of the immunoassays is suitable for detection of DCF at the environmental quality standard level set in seawater, that is, 10 ng/L. The precision of the proposed fluidic method was studied at three distinct concentration levels of DCF in seawater that covered 3 orders of magnitude, viz., 0.01, 0.1, and 1.0 ng mL −1 .…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Although these methods are selective and sensitive, they are not easily amenable to on-site detection. In this context, various biosensing set ups have been implemented using antibodies, 18 aptamers 19,20 or even whole cells [21][22][23] as bioreceptors coupled to electrochemical [24][25][26] or optical 27,28 signal transduction. With such set ups, DCF could be quantified in various matrices with variable sensitivities.…”
Section: -17mentioning
confidence: 99%
“…Chromatographic methods are routinely used to quantify DCF residues in surface and ground waters. , Alternatively, label-based immunochemical assays allow to quantify DCF in water samples with sensitivities from the μg/L down to the sub-ng/L range, depending on the detection method. Although these methods are selective and sensitive, they are not easily amenable to on-site detection. In this context, various biosensing setups have been implemented using antibodies, aptamers, , or even whole cells as bioreceptors coupled to electrochemical or optical , signal transduction. With such setups, DCF could be quantified in various matrices with variable sensitivities.…”
mentioning
confidence: 99%
“…Faster immunoassays developed for DCF comprise an upconversion-linked immunosorbent assay (ULISA) [26], a fluorescence polarization immunoassay (FPIA) [27], and a suspension array fluorescence immunoassay (SAFIA) [28]. Steps forward to mobile and automated sensing of diclofenac have been made with several immunosensors for the detection of DCF reported in recent years [29][30][31][32][33][34][35].…”
Section: Introductionmentioning
confidence: 99%