2016
DOI: 10.1016/j.actbio.2016.04.005
|View full text |Cite
|
Sign up to set email alerts
|

Diagenesis-inspired reaction of magnesium ions with surface enamel mineral modifies properties of human teeth

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 31 publications
(26 citation statements)
references
References 45 publications
0
24
0
2
Order By: Relevance
“…Tooth enamel sections fixed in resin blocks were also analyzed for comparison. 33,34 Nine measurements were obtained per specimen (n 5 3) under indentation load of 500 g for 10 s of dwell time. Computer software (Vision PE 3.5, Clemex Technologies Inc., Shawnee Mission, KS) was used to measure the microhardness value at the site of indentation from images captured by a built-in camera.…”
Section: Mechanical Characterizationmentioning
confidence: 99%
“…Tooth enamel sections fixed in resin blocks were also analyzed for comparison. 33,34 Nine measurements were obtained per specimen (n 5 3) under indentation load of 500 g for 10 s of dwell time. Computer software (Vision PE 3.5, Clemex Technologies Inc., Shawnee Mission, KS) was used to measure the microhardness value at the site of indentation from images captured by a built-in camera.…”
Section: Mechanical Characterizationmentioning
confidence: 99%
“…The etching time was set at 50 s per cycle and was repeated for six cycles. These conditions correspond to an etch rate of 0.28 nm/s on a Ta 2 O 5 sample . Because PDLLA films are less resistant to etching than Ta 2 O 5 ; the expected etching rate would be higher than 0.28 nm/s for PDLLA.…”
Section: Methodsmentioning
confidence: 97%
“…These conditions correspond to an etch rate of 0.28 nm/s on a Ta 2 O 5 sample. 39 Because PDLLA films are less resistant to etching than Ta 2 O 5 ; the expected etching rate would be higher than 0.28 nm/s for PDLLA. Data analysis was performed using the Avantage software (5.41v, Thermo Fisher Scientific Inc., East Grinstead, UK).…”
Section: Compatibility Of the Molding Materials With Pdllamentioning
confidence: 99%
“…Numerous works [3][4][5][6][7][10][11][12][13][14] are dedicated to the study of properties of biominerals (enamel, bones) and organic poly-Методом електронного парамагнітного резонансу вивчені електропровідні області в біомінералах (емаль зубів, кістки), і в полі-амідних полотнах, що містять наночас-тинки поліаніліну. Встановлено, що харак-теристики електронного парамагнітного резонансу електропровідних нанообластей в біомінералах і текстильних матеріалах, що містять наночастинки поліаніліну, є подібними.…”
Section: Literature Review and Problem Statementunclassified
“…Встановлено, що харак-теристики електронного парамагнітного резонансу електропровідних нанообластей в біомінералах і текстильних матеріалах, що містять наночастинки поліаніліну, є подібними. Це обумовлено схожістю пара-магнітних носіїв заряду, локалізованих в нанорозмірних електропровідних областях біомінералів і органічних полімерів [10], however variation of EPR signals under effect of metal ions of various concentrations on properties of human teeth and bones was not taken in account. Work [6] investigated properties of enamel by the method of optically stimulated luminescence (OSL).…”
Section: Literature Review and Problem Statementunclassified